Loss of Data on ARINC Bus from the CFDIU for Engine 1
TASK 73-25-00-810-881-A
Loss of Data on ARINC Bus from the CFDIU for Engine 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 73-25-00-710-186-A ** ON A/C NOT FOR ALL
Subtask 73-25-00-810-118-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:45 UTC
Loss of Data on ARINC Bus from the CFDIU for Engine 1
1. Possible Causes
- EIU-1 [1KS1]
wiring from the EIU-1 (1KS1) pins AA/11C, 12B to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 732506 | |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
| AMM 73-25-34-710-040 | Operational Test of the Engine Interface Unit |
Subtask 73-25-00-710-186-A ** ON A/C NOT FOR ALL
A. Not applicable.
4. Fault IsolationSubtask 73-25-00-810-118-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message EIU 1 : NO CFDIU DATA:
Subtask 73-25-00-710-187-A ** ON A/C NOT FOR ALL - replace the EIU-1 [1KS1] , AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
- do a check and repair the
wiring from the EIU-1 (1KS1) pins AA/11C, 12B to the first terminal block ASM 732506.