Loss of Data on the Secondary ECS Bus to the EIU 2
TASK 73-25-00-810-878-A
Loss of Data on the Secondary ECS Bus to the EIU 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 73-25-00-710-216-A ** ON A/C NOT FOR ALL Subtask 73-25-00-710-216-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 73-25-00-810-133-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:45 UTC
Loss of Data on the Secondary ECS Bus to the EIU 2
1. Possible Causes
- EIU-2 [1KS2]
wiring from the EIU-2 (1KS2) pins AA/3J, 3K to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 732506 | |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
| AMM 73-25-34-710-040 | Operational Test of the Engine Interface Unit |
| AMM 73-25-34-710-043 | Operational Test of the Engine Interface Unit |
Subtask 73-25-00-710-216-A ** ON A/C NOT FOR ALL Subtask 73-25-00-710-216-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 73-25-00-810-133-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message EIU 2 : NO ZONE CONT S DATA:
Subtask 73-25-00-710-217-A ** ON A/C NOT FOR ALL - replace the EIU-2 [1KS2] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
- do a check and repair the
wiring from the EIU-2 (1KS2) pins AA/3J, 3K to the first terminal block ASM 732506.
B. Do the test given in Para. 3.A.