W DOC AIRBUS | TSM A320F

Loss of Data on the Second and Primary ECS Buses to the EIU 2


TASK 73-25-00-810-874-A
Loss of Data on the Second and Primary ECS Buses to the EIU 2


1. Possible Causes
  • CONT-AIR COND SYSTEM 1 [47HH]
  • CONT-AIR COND SYSTEM 2 [57HH]
  • wiring
  • EIU-2 [1KS2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AWM 732520
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
3. Fault Confirmation
Subtask 73-25-00-710-208-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable.
Subtask 73-25-00-710-208-B ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable.
4. Fault Isolation
Subtask 73-25-00-810-129-C ** ON A/C NOT FOR ALL
A. If the fault is also present on engine 2:
   (1) If the fault is present on engine 2 only:
  • do a check of the wiring between the EIU2 (1KS2) pins AA/2J, AA/2K and terminal block 1853VT and between the EIU2 (1KS2) pins AA/3J, AA/3K and terminal block 1862VT AWM 732520.
     (a) If the wiring is not correct:
  • Repair as required.
     (b) If the wiring is correct:
Subtask 73-25-00-710-209-A ** ON A/C NOT FOR ALL
B. No additional maintenance action is required if the fault is not confirmed.
   (1) Repeat the fault isolation procedure if the fault continues.
[Rev.8 from Aug 2018] 2026.04.04 04:35:45 UTC