Failure of the N2 Higher than the Minimum TO Discrete Output on the EIU 2
TASK 73-25-00-810-864-A
Failure of the N2 Higher than the Minimum TO Discrete Output on the EIU 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 73-25-00-710-176-A ** ON A/C NOT FOR ALL Subtask 73-25-00-710-176-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 73-25-00-810-204-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:43 UTC
Failure of the N2 Higher than the Minimum TO Discrete Output on the EIU 2
1. Possible Causes
- P2 CONTROLLER [27HH]
- EIU-2 [1KS2]
wiring from the EIU-2 (1KS2) to the pack 2 temperature controller (27HH) - CONT-AIR COND SYSTEM 2 [57HH]
wiring from the EIU-2 (1KS2) to the pack 2 temperature controller (57HH)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-34-000-001 | Removal of the Pack Controller |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-001 | Installation of the Pack Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| ASM 732509 | |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
| AMM 73-25-34-710-040 | Operational Test of the Engine Interface Unit |
| AMM 73-25-34-710-043 | Operational Test of the Engine Interface Unit |
Subtask 73-25-00-710-176-A ** ON A/C NOT FOR ALL Subtask 73-25-00-710-176-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 73-25-00-810-204-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK PACK CONT 7HH EIU 2 CIRCUIT:
Subtask 73-25-00-810-204-B ** ON A/C NOT FOR ALL - replace the P2 CONTROLLER [27HH] AMM 21-61-34-000-001 and AMM 21-61-34-400-001.
- replace the EIU-2 [1KS2] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
- do a check and repair the
wiring from the EIU-2 (1KS2) to the pack 2 temperature controller (27HH) pin AB/1G to pin AA/10B ASM 732509.
A. If the test gives the maintenance message CHECK PACK CONT 7HH EIU 2 CIRCUIT:
Subtask 73-25-00-710-177-A ** ON A/C NOT FOR ALL NOTE: CONT-PACK (7HH) has been replaced by AIR COND SYS 2 (57HH) due to a modification of the Air Conditioning System.
- replace the CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
- replace the EIU-2 [1KS2] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
- do a check and repair the
wiring from the EIU-2 (1KS2) to the pack 2 temperature controller (57HH) pin AB/1G to pin AB/3C ASM 732509.
B. Do the test given in Para. 3.A.