W DOC AIRBUS | TSM A320F

Failure of the N2 Higher than the Minimum TO Discrete Output on the EIU 1


TASK 73-25-00-810-863-A
Failure of the N2 Higher than the Minimum TO Discrete Output on the EIU 1


1. Possible Causes
  • P1 CONTROLLER [7HH]
  • EIU-1 [1KS1]
  • wiring from the EIU-1 (1KS1) to the pack 1 temperature controller (7HH)
  • CONT-AIR COND SYSTEM 1 [47HH]
  • wiring from the EIU-1 (1KS1) to the pack 1 temperature controller (47HH)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-001
Removal of the Pack Controller
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-001
Installation of the Pack Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
ASM 732509
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-040
Operational Test of the Engine Interface Unit
AMM 73-25-34-710-043
Operational Test of the Engine Interface Unit
3. Fault Confirmation
Subtask 73-25-00-710-174-A ** ON A/C NOT FOR ALL
A. Do the operational test of the engine interface unit through the CFDS AMM 73-25-34-710-040.
Subtask 73-25-00-710-174-B ** ON A/C NOT FOR ALL
A. Do the operational test of the engine interface unit through the CFDS AMM 73-25-34-710-043.
4. Fault Isolation
Subtask 73-25-00-810-112-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK PACK CONT 7HH EIU 1 CIRCUIT:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the EIU-1 (1KS1) to the pack 1 temperature controller (7HH) pin AB/1G to pin AA/10B ASM 732509.
Subtask 73-25-00-810-112-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK PACK CONT 7HH/EIU1 CIRCUIT:
NOTE: CONT-PACK (7HH) has been replaced by AIR COND SYS 1 (47HH) due to a modification of the Air Conditioning System.
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the EIU-1 (1KS1) to the pack 1 temperature controller (47HH) pin AB/1G to pin AB/3C ASM 732509.
Subtask 73-25-00-710-175-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.