W DOC AIRBUS | TSM A320F

Failure of the Annunciator Light Test and Interface Board for Engine 2


TASK 73-25-00-810-858-A
Failure of the Annunciator Light Test and Interface Board for Engine 2


1. Possible Causes
  • BOARD-ANN LT TEST & INTFC [19LP]
  • EIU-2 [1KS2]
  • wiring from the EIU-2 (1KS2) to the board (19LP).
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-14-33-000-001
Removal of the Annunciator-Light Test and Interface-Board
AMM 33-14-33-400-001
Installation of the Annunciator-Light Test and Interface-Board
ASM 732509
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-040
Operational Test of the Engine Interface Unit
AMM 73-25-34-710-043
Operational Test of the Engine Interface Unit
3. Fault Confirmation
Subtask 73-25-00-710-164-A ** ON A/C NOT FOR ALL
A. Test Do the operational test of the engine interface unit through the CFDS AMM 73-25-34-710-040.
Subtask 73-25-00-710-164-B ** ON A/C NOT FOR ALL
A. Test Do the operational test of the engine interface unit through the CFDS AMM 73-25-34-710-043.
4. Fault Isolation
Subtask 73-25-00-810-107-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK 19LP RELAY CIRCUIT OR EIU 2:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the EIU-2 (1KS2) to the board (19LP). pin AB/9A to pin AA/3 ASM 732509.
Subtask 73-25-00-710-165-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:35:43 UTC