Failure of the Relay 15KS1 Control on the EIU 1
TASK 73-25-00-810-851-A
Failure of the Relay 15KS1 Control on the EIU 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 73-25-00-710-150-A ** ON A/C NOT FOR ALL
Subtask 73-25-00-810-100-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:42 UTC
Failure of the Relay 15KS1 Control on the EIU 1
1. Possible Causes
- EIU-1 [1KS1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
| AMM 73-25-34-710-041 | Read The Class 3 Faults |
| AMM 73-25-34-710-044 | Read the Class 3 Faults |
Subtask 73-25-00-710-150-A ** ON A/C NOT FOR ALL
A. Test
Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) to read the Class 3 Faults AMM 73-25-34-710-041.
Subtask 73-25-00-710-150-B ** ON A/C NOT FOR ALL Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) to read the Class 3 Faults AMM 73-25-34-710-041.
A. Test
Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) to read the Class 3 Faults AMM 73-25-34-710-044.
4. Fault IsolationDo the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) to read the Class 3 Faults AMM 73-25-34-710-044.
Subtask 73-25-00-810-100-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK 15KS1 RELAY CIRCUIT OR EIU 1:
Subtask 73-25-00-710-151-A ** ON A/C NOT FOR ALL - replace the EIU-1 [1KS1] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
NOTE: As relay 15KS1 is not installed, no maintenance action in line is necessary. When the message comes into view on the EIU Class 3 report, replace the EIU 1 at the "A" check that follows.
B. If the EIU 1 (1KS1) is replaced:
- do the test given in Para. 3.A.