Failure of the T/R CTL INHIBITION Discrete Output on EIU 1



1. Possible Causes
· RELAY-THRUST REV INHIBITION, ENG 1 ( 14KS1 )
· EIU-1 ( 1KS1 )
· wiring from the EIU 1 (1KS1) to the relay (14KS1)
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. ASM 73-25-16
Ref. AMM 73-25-34-000-041 Removal of the Engine Interface Unit (EIU)
Ref. AMM 73-25-34-400-041 Installation of the Engine Interface Unit (EIU)
Ref. AMM 73-25-34-710-042 Operational Test of the EIU with the CFDS
3. Fault Confirmation
Subtask 73-25-00-710-128-A
A. Test
(1) Do the operational test of the EIU 1 with the CFDS Ref. AMM 73-25-34-710-042 .
4. Fault Isolation
Subtask 73-25-00-810-089-A
A. If the operational test gives the maintenance message T/R INOP CHECK 14KS1 OR EIU1:
· replace the RELAY-THRUST REV INHIBITION, ENG 1 ( 14KS1 ) .
(1) If the fault continues:
· replace the EIU-1 ( 1KS1 ) , Ref. AMM 73-25-34-000-041 and Ref. AMM 73-25-34-400-041 .
(2) If the fault continues:
· do a check and repair the wiring from the EIU 1 (1KS1) to the relay (14KS1) pin AB/10A to pin X
Ref. ASM 73-25-16.
Subtask 73-25-00-710-129-A
B. Do the test given in Para. 3. [Rev.6 from Feb 2017] 2026.04.04 04:36:24 UTC