W DOC AIRBUS | TSM A320F

Loss of the Engine Group 1 Solenoids on Engine 1



1. Possible Causes
· wiring
· EEC ( 4000KS )
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power
Ref. AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External
Power
Ref. AMM 31-60-00-860-002 EIS Stop Procedure
Ref. AMM 71-00-00-710-018 Discontinued Start, Restart and Shutdown Procedures
Ref. AMM 71-00-00-710-043 Normal Engine Automatic Start Procedure
Ref. AMM 71-00-00-710-047 Normal Engine Manual Start Procedure
Ref. AMM 71-13-00-010-010 Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
Ref. AMM 71-13-00-410-010 Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
Ref. AMM 73-22-34-000-010 Removal of the Electronic Engine Control (EEC)
Ref. AMM 73-22-34-400-010 Installation of the Electronic Engine Control (EEC)
Ref. ASM 73-25-18
3. Fault Confirmation
Subtask 73-22-00-860-068-A
A. Job Set-up
(1) Energize the aircraft electrical circuits
Ref. AMM 24-41-00-861-002 .
(2) On the panel 50VU, release the ENG FADEC GND PWR 1 pushbutton switch.
Subtask 73-22-00-710-094-A
B. Test
(1) On the panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch and release it again.
NOTE: This action resets the FADEC memory.
(2) Adjust the brightness of the MCDU screen.
(3) Push the INIT mode key. The INIT page comes into view.
(4) Enter a new flight number.
(5) Start the engine 1 by the normal engine automatic start procedure Ref. AMM 71-00-00-710-043 or
the normal engine manual start procedure Ref. AMM 71-00-00-710-047 .
NOTE: Operation of the engine for at least 3 minutes erases the LAST LEG REPORT related to the
last flight and the new fault is recorded in the EEC LAST LEG REPORT.
(6) Do a shutdown of the engine 1 by the discontinued start, restart and shutdown procedure Ref.
AMM 71-00-00-710-018 .
(7) Read the LAST LEG REPORT and the scheduled maintenance report of the FADEC (1A and 1B)
menu on the MCDU (Ref. 70-00-00 Page Block 301 Task Supporting Data).
(a) Make a record of the maintenance message.
(b) Make a record of the channel FADEC 1A or FADEC 1B which found the fault.
(8) Fully decrease the brightness of the MCDU screen (display off).
4. Fault Isolation
Subtask 73-22-00-810-072-A
A. If the test gives the maintenance message ENG GROUP 1 SOL/EEC 1 and if the channel which found the
fault is FADEC 1A:
· open the fan cowls 437AL and 438AR Ref. AMM 71-13-00-010-010
· do a check of the solenoids for shorts across their windings, shorts to ground and for open circuits
caused by short circuit at the:
. wiring at the HPC solenoid valve connector (4020KS3-A) between pins 3 and 4
. wiring at the HPC solenoid valve connector (4020KS1-A) between pins 3 and 4 Ref. ASM
73-25-18.
(1) If the wiring is not correct:
· repair the above wiring.
(2) If the wiring is correct:
· replace the EEC ( 4000KS ) Ref. AMM 73-22-34-000-010 and Ref. AMM 73-22-34-400-010 .
Subtask 73-22-00-810-073-A
B. If the test gives the maintenance message ENG GROUP 1 SOL/EEC 1 and if the channel which found the
fault is FADEC 1B:
· open the fan cowls 437AL and 438AR Ref. AMM 71-13-00-010-010
· do a check of the solenoids for shorts across their windings, shorts to ground and for open circuits
caused by short circuit at the:
. wiring at the HPC solenoid valve connector (4020KS3-A) between pins 6 and 7
. wiring at the HPC solenoid valve connector (4020KS1-A) between pins 6 and 7 Ref. ASM
73-25-18.
(1) If the wiring is not correct:
· repair the above wiring.
(2) If the wiring is correct:
· replace the EEC ( 4000KS ) Ref. AMM 73-22-34-000-010 and Ref. AMM 73-22-34-400-010 .
Subtask 73-22-00-710-095-A
C. Do the test given in Para. 3.
5. Close-up
Subtask 73-22-00-860-069-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
Ref. AMM 31-60-00-860-002 .
(2) On the panel 50VU, push the ENG FADEC GND PWR 1 pushbutton switch.
(3) De-energize the aircraft electrical circuits
Ref. AMM 24-41-00-862-002 .
(4) Make sure that the fan cowls 437AL and 438AR are closed Ref. AMM 71-13-00-410-010 . [Rev.6 from Feb 2017] 2026.04.04 04:36:17 UTC