W DOC AIRBUS | TSM A320F

T3 Sensor Electrical Failure on Channel A and B


TASK 73-21-01-810-974-A
T3 Sensor Electrical Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-21-00-810-862-A
T3 Sensor Electrical Failure Channel A
TSM TASK 73-21-00-810-863-A
T3 Sensor Electrical Failure Channel B
3. Fault Confirmation
Subtask 73-21-01-710-217-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 73-21-01-810-475-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 73-21-00-810-862).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 73-21-00-810-863).
5. Close-up
Subtask 73-21-01-860-213-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:44 UTC