W DOC AIRBUS | TSM A320F

ARINC Out Bus Wraparound Failure on Channel A and B (Transmitters TX2 Wraparound Signal Failures)


TASK 73-21-01-810-971-A
ARINC Out Bus Wraparound Failure on Channel A and B (Transmitters TX2 Wraparound Signal Failures)


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-21-00-810-887-A
ARINC Out Bus Wraparound Failure (Transmitters TX2 Wraparound Signal Failures) Channel A
TSM TASK 73-21-00-810-888-A
ARINC Out Bus Wraparound Failure (Transmitters TX2 Wraparound Signal Failures) Channel B
3. Fault Confirmation
Subtask 73-21-01-710-214-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 73-21-01-810-472-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 73-21-00-810-887).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 73-21-00-810-888).
5. Close-up
Subtask 73-21-01-860-210-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:44 UTC