W DOC AIRBUS | TSM A320F

DASH of Engine 2 parameter on ECAM



1. Possible Causes
· continuity check of connectors J1 and J7 between pins T and Q
· continuity check of connectors J1 and J7 between pins T and R
· configuration of 407VC2
· connection of connectors J1, J7 and 407VC2
· pin retention of connectors J1,J7 and 407VC2
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power
Ref. AMM 70-23-15-912-010 Connection of Electrical Connectors
Ref. AMM 71-50-00-210-010 Wire Harness Visual Inspection - All Power Plant Electrical Cables
Ref. AWM 73-25-03
Ref. ASM 73-25-05
3. Fault Confirmation
Subtask 73-20-00-860-075-A
A. Energize the aircraft electrical circuits
Ref. AMM 24-41-00-861-002
Subtask 73-20-00-865-071-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANEL DESIGNATION FIN LOCATION
49VU ENGINE/2/FADEC A/AND EIU 2 2KS2 A05
49VU ENGINE/1 AND 2/IGN/SYS A 1JH A03
121VU ENGINE/IGN/ENG2/SYS B 3JH2 P42
121VU ENGINE/IGN/ENG2/SYS A BAT 2JH2 P40
121VU ENGINE/ENG2/FADEC B/AND EIU 2 4KS2 Q40
Subtask 73-20-00-710-345-A
C. Check for dash on engine parameters on ECAM display
4. Fault Isolation
Subtask 73-20-00-810-290-A
A. If the fault is confirmed:
(1) Disconnect J1 and J7 connectors from EEC2.
(a) Do a continuity check of connectors J1 and J7 between pins T and Q
(b) Do a continuity check of connectors J1 and J7 between pins T and R
(c) if fault found, do step 4.A.(2).
(d) if no fault found, do step 4.A.(3).
(2) Disconnect the connector 407VC2 in pylon (424).
(a) Check configuration of 407VC2 Ref. ASM 73-25-05 and Ref. AWM 73-25-03.
(3) If the fault continues:
· Inspect harness between EEC2 and 407VC2 Ref. AMM 71-50-00-210-010
· Check connection of connectors J1, J7 and 407VC2 Ref. AMM 70-23-15-912-010
· Check pin retention of connectors J1,J7 and 407VC2 (Ref. ESPM 20-48-23)
· Repair as necessary.
Figure 73(IAE)-20-00-991-00100-13-A- / SHEET 1/1 - ADIRU 1
Figure 73(IAE)-20-00-991-00200-13-A- / SHEET 1/1 - ADIRU 2
Figure 73(IAE)-20-00-991-00600-13-A- / SHEET 1/1 - ADIRU 1
Figure 73(IAE)-20-00-991-00700-13-A- / SHEET 1/1 - ADIRU 2
73-22 - (IAE) - FADEC SYSTEM
73-22-00 - (IAE) - FADEC SYSTEM
73-22-00 PB 201 CONF 13 - FADEC SYSTEM - FAULT ISOLATION PROCEDURES [Rev.6 from Feb 2017] 2026.04.04 04:36:15 UTC