W DOC AIRBUS | TSM A320F

loss of the T12 Sensor Signal through the two Channels on Engine 2


TASK 73-20-00-810-924-A
loss of the T12 Sensor Signal through the two Channels on Engine 2


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-20-00-810-862-A
Loss of T12 Sensor Signal through the Channel A on Engine 2
TSM TASK 73-20-00-810-864-A
Loss of T12 Sensor Signal through the Channel B on Engine 2
AMM 73-29-00-710-040
Operational Test of the FADEC on the ground (with Engine Motoring)
3. Fault Confirmation
Subtask 73-20-00-710-243-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the FADEC 2A and 2B on the ground (with engine motoring) AMM 73-29-00-710-040.
4. Fault Isolation
Subtask 73-20-00-810-194-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance messages T12 SNSR, J9, ECU and T12 SNSR, J10, ECU: