Loss of the Output B Bus on EIU 2
TASK 73-20-00-810-847-A
Loss of the Output B Bus on EIU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 73-20-00-865-060-A ** ON A/C NOT FOR ALL
Subtask 73-20-00-810-097-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:19 UTC
Loss of the Output B Bus on EIU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 73-21-60-000-001 | Removal of the Electronic Control Unit (ECU) |
| AMM 73-21-60-400-001 | Installation of the Electronic Control Unit (ECU) |
| ASM 732505 | |
| ASM 732506 | |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
Subtask 73-20-00-865-060-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 73-20-00-710-112-A ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 121VU | ENGINE/ENG2/FADEC B/AND EIU 2 | 4KS2 | Q40 |
Subtask 73-20-00-810-097-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FWC2 : NO DATA FROM EIU2:
Subtask 73-20-00-710-113-A ** ON A/C NOT FOR ALL - do a check for 28VDC at EIU 2 pins AC/9, 11.
- replace the EIU-2 [1KS2] AMM 73-25-34-000-040 and AMM 73-25-34-400-040 ASM 732505.
- do a check and repair the
wiring from the EIU 2 (1KS2) pins AB/5H, 5K to the first terminal block ASM 732506.
- replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
B. Do the test given in Para. 3.