W DOC AIRBUS | TSM A320F

RTT Feedback Proximity Sensor Electrical Failure on Channel A and B


TASK 73-13-00-810-812-A
RTT Feedback Proximity Sensor Electrical Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-13-00-810-801-A
RTT Feedback Proximity Sensor Electrical Failure Channel A
TSM TASK 73-13-00-810-802-A
RTT Feedback Proximity Sensor Electrical Failure Channel B
3. Fault Confirmation
Subtask 73-13-00-710-064-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 73-13-00-810-061-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 73-13-00-810-801).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 73-13-00-810-802).
5. Close-up
Subtask 73-13-00-860-061-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:37 UTC