Flexible Temperature not Entered


TASK 73-00-00-810-870-A
Flexible Temperature not Entered


1. Possible Causes
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 732506
3. Fault Confirmation
Subtask 73-00-00-710-186-A ** ON A/C NOT FOR ALL
A. Test
   (1) On the MCDU, make sure that the FLEX TEMP value is correctly entered.
4. Fault Isolation
Subtask 73-00-00-810-120-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the ECAM warning message FLEX TEMP NOT SET:
NOTE: Do this procedure on the two engines.
  • do a check and repair the aircraft wiring between the MCDU (3CA1) (3CA2)/FCU (2CA)/FMGC (1CA1) (1CA2)/EIU (1KS1) (1KS2) and the ECU (4000KS) ASM 732506.
Subtask 73-00-00-710-187-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.