W DOC AIRBUS | TSM A320F

Impossibility to Open the Aft Avionics Compartment Door


TASK 52-41-00-810-820-A
Impossibility to Open the Aft Avionics Compartment Door


1. Possible Causes
  • avionics compartment aft door
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 52-41-14-000-001
Removal of the Avionics-Compartment Aft Door
AMM 52-41-14-400-001
Installation of the Avionics-Compartment Aft Door
3. Fault Confirmation
Subtask 52-41-00-860-065-A
A. Job Set-up
   (1) Put the access platform in position at zone 128.
Subtask 52-41-00-710-065-A
B. Test
   (1) Make sure that you cannot open the aft avionics compartment door.
4. Fault Isolation
Subtask 52-41-00-810-065-A
A. If the test confirms the fault:
  • get access to the avionics compartment by another avionics compartment door
  • release the locking mechanism which is inside the blocked door
  • replace the avionics compartment aft door AMM 52-41-14-000-001 and AMM 52-41-14-400-001.
[Rev.8 from Aug 2018] 2026.04.04 04:34:54 UTC