W DOC AIRBUS | TSM A320F

Impossibility to Open the Right Avionics Compartment Door


TASK 52-41-00-810-819-A
Impossibility to Open the Right Avionics Compartment Door


1. Possible Causes
  • avionics compartment right door
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 52-41-13-000-001
Removal of the Avionics-Compartment Lateral-Right Door
AMM 52-41-13-400-001
Installation of the Avionics-Compartment Lateral-Right Door
3. Fault Confirmation
Subtask 52-41-00-860-064-A
A. Job Set-up
   (1) Put the access platform in position at zone 126.
Subtask 52-41-00-710-064-A
B. Test
   (1) Make sure that you cannot open the right avionics compartment door.
4. Fault Isolation
Subtask 52-41-00-810-064-A
A. If the test confirms the fault:
  • get access to the avionics compartment by another avionics compartment door
  • release the locking mechanism which is inside the blocked door
  • replace the avionics compartment right door AMM 52-41-13-000-001 and AMM 52-41-13-400-001.
[Rev.8 from Aug 2018] 2026.04.04 04:34:54 UTC