W DOC AIRBUS | TSM A320F

Closing of the L Avionics Compartment Door Not Possible


TASK 52-41-00-810-810-A
Closing of the L Avionics Compartment Door Not Possible


1. Possible Causes
  • locking rod
  • roller
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 52-41-12-000-001
Removal of the Avionics-Compartment Lateral-Left Door
AMM 52-41-12-400-001
Installation of the Avionics-Compartment Lateral-Left Door
CMM 524132
3. Fault Confirmation
Subtask 52-41-00-860-059-A
A. Job Set-up
   (1) Put the access platform in position in the zone 125.
Subtask 52-41-00-710-059-A
B. Test
   (1) Make sure that the L avionics compartment door cannot be closed.
4. Fault Isolation
Subtask 52-41-00-810-055-A
A. If the test confirms the fault:
   (1) Do a check and repair the locking rod or the roller CMM 524132.
   (2) Install the L avionics compartment door (812) AMM 52-41-12-400-001.
[Rev.8 from Aug 2018] 2026.04.04 04:34:54 UTC