Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Left Avionics-Compartment Door
TASK 52-41-00-810-801-A
Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Left Avionics-Compartment Door
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 52-41-00-860-050-A
Subtask 52-41-00-810-050-A
Subtask 52-41-00-860-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:53 UTC
Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Left Avionics-Compartment Door
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| ASM 315405 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| AMM 52-71-00-820-008 | Adjustment of the Proximity Switches of the Avionics Compartment Doors 811, 812 and 824 |
| AMM 52-71-14-000-001 | Removal of the Proximity Switches of the Avionics Compartment Doors |
| AMM 52-71-14-400-001 | Installation of the Proximity Switches of the Avionics Compartment Doors |
Subtask 52-41-00-860-050-A
A. Job Set-Up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 52-41-00-710-050-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
(1) On the ECAM control panel:
4. Fault Isolation(1) On the ECAM control panel:
- push the DOOR key to get the DOOR/OXY page.
Subtask 52-41-00-810-050-A
A. If the test confirms the fault:
Subtask 52-41-00-710-051-A - do a check for 28VDC between pins A and D of door frame proximity switch (23WV) ASM 315405.
- repair the wiring as necessary.
- disconnect the connector of the door frame proximity switch (23WV)
- install the jumper wire between the pins B and C of the door frame proximity switch (23WV) ASM 315405
- do the test given in Para 3.B.
- do a check for a ground signal at pin C of the door frame proximity switch (23WV) ASM 315405.
- repair the wiring from the pin C of the door frame proximity switch (23WV) to the ground terminal.
- do a check and repair the wiring from the door frame proximity switch (23WV) to the SDAC-1(2) (1WV1(2)) pin B to pin AD/11E ASM 315405.
- remove the jumper wire between the pins B and C of the door frame proximity switch (23WV)
- connect the connector of the door frame proximity switch (23WV)
- adjust the door frame proximity switch (23WV) with the doors checking tool AMM 52-71-00-820-008 or with the ECAM system AMM 52-71-00-820-008.
- replace the PROX SW-FRAME, L AVIONICS COMPT DOOR [23WV] AMM 52-71-14-000-001 and AMM 52-71-14-400-001.
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
B. Test
(1) On the ECAM control panel:
5. Close-up(1) On the ECAM control panel:
- push the DOOR key to get the DOOR/OXY page.
Subtask 52-41-00-860-051-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.