1. Possible Causes
- MAN SEL VALVE-AFT CARGO DOOR [2504MJ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 523501 | |
| AWM 523501 | |
| AMM 52-36-15-000-001 | Removal of the Manual Selector Valve |
| AMM 52-36-15-400-001 | Installation of the Manual Selector Valve |
Subtask 52-36-00-860-058-A
A. Aircraft Maintenance Configuration
(1) Make sure that the FWD cargo door is in this condition:
(a) Push the handle flap in to release the door handle from the catch of the door structure.
4. Fault Isolation(1) Make sure that the FWD cargo door is in this condition:
- a second person does not operate the FWD cargo door
- the selector of the MAN SEL VALV -FWD CARGO DOOR (2501MJ) is in the NEUTRAL position.
(a) Push the handle flap in to release the door handle from the catch of the door structure.
WARNING:
MAKE SURE THAT THE TRAVEL RANGE OF THE CARGO DOOR IS CLEAR BEFORE YOU UNLOCK IT. STAY AFT OF (LEFT OF) THE DOOR WHEN YOU UNLOCK IT BECAUSE IT CAN OPEN SUDDENLY AND CAUSE INJURY.
(b) Move the door handle to the UNLOCKED position. Subtask 52-36-00-810-065-A
A. The fault confirmation gives that the ELEC PUMP-Y (3075GX) starts to operate:
(a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] , AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
(3) If the selector is in the NEUTRAL position but the ELEC PUMP-Y (3075GX) does not stop the operation:
(a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] AMM 52-36-15-000-001 AMM 52-36-15-400-001.
(b) If there is no continuity:
(a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] AMM 52-36-15-000-001 AMM 52-36-15-400-001.
(b) If there is no continuity:
5. Close-up- Make sure that the selector of the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] is in the NEUTRAL position.
- Put the selector manually back in the NEUTRAL position to stop the operation of the ELEC PUMP-Y (3075GX).
(a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] , AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
(3) If the selector is in the NEUTRAL position but the ELEC PUMP-Y (3075GX) does not stop the operation:
- Do a check for continuity between connector A/A and connector A/B of MAN SEL VALVE-AFT CARGO DOOR [2504MJ] ASM 523501.
(a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] AMM 52-36-15-000-001 AMM 52-36-15-400-001.
(b) If there is no continuity:
- Do a check and repair the wiring between the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connector A/B and the LGCIU-2 (5GA2) connector AA/7B ASM 523501.
(a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] AMM 52-36-15-000-001 AMM 52-36-15-400-001.
(b) If there is no continuity:
- Do a check and repair the wiring between the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connector A/C and the ground terminal (6798VN) AWM 523501.
Subtask 52-36-00-869-057-A
A. Unlatch the aft cargo door as given in Para. 3.A to make sure that the ELEC PUMP-Y (3075GX) does not start to operate.