W DOC AIRBUS | TSM A320F

Fault during the Closing Procedure of the Aft Cargo-Compartment Door


TASK 52-36-00-810-804-A
Fault during the Closing Procedure of the Aft Cargo-Compartment Door


1. Possible Causes
  • PACKAGE E-PUMP [3075GX]
  • RELAY (15MJ)
  • wiring
  • RELAY-TIME [6MJ]
  • RELAY-L/G POSITION, SYS 2 [12GB]
  • LGCIU-2 [5GA2]
  • MAN SEL VALVE-AFT CARGO DOOR [2504MJ]
  • C/B-DOORS/CARGO [1MJ]
  • SW-LOCKING SHAFT [12MJ]
  • 4VD
  • ACTUATOR-AFT CARGO DOOR, FWD [2505MJ]
  • ACTUATOR-AFT CARGO DOOR, AFT [2506MJ]
  • SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ]
  • RELAY (13MJ)
  • RELAY (14MJ)
  • VALVE-DOUBLE CHECK [3717GM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 32-31-00-810-802-A
LGCIU Fault
TSM TASK 32-31-00-810-835-A
Cargo Door (Aft) Lockshaft Proximity Sensor Fault (12MJ)
ESPM 204423
AMM 52-30-00-860-001
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
AMM 52-30-00-860-003
Open the FWD or Aft Cargo-Compartment Door with the Hand Pump
ASM 523501
AMM 52-35-13-400-002
Installation of the Proximity Switches
AMM 52-36-12-000-001
Removal of the Electro-Manual Selector Valve
AMM 52-36-12-400-001
Installation of the Electro-Manual Selector Valve
AMM 52-36-13-000-001
Removal of Double Check Valve
AMM 52-36-13-400-001
Installation of Double Check Valve
AMM 52-36-15-000-001
Removal of the Manual Selector Valve
AMM 52-36-15-400-001
Installation of the Manual Selector Valve
AMM 52-36-18-000-001
Removal of the Door Actuator
AMM 52-36-18-400-001
Installation of the Door Actuator
3. Fault Confirmation
Subtask 52-36-00-860-053-A
A. Aircraft Maintenance Configuration
   (1) Close the aft cargo compartment door (referred to as cargo door) in the normal mode AMM 52-30-00-860-001.
NOTE: Make sure that a second person does not operate the FWD cargo door.
   (2) Close the FWD cargo door in the normal mode AMM 52-30-00-860-001.
NOTE: Make sure that a second person does not operate the aft cargo door.
4. Fault Isolation
Subtask 52-36-00-810-053-H
A. If the fault confirmation gives that only the sft cargo door does not close and the PACKAGE E-PUMP [3075GX] does not operate (fault in the door control system):
  • Do a check for 28 VDC between
    The RELAY (15MJ) connector A/A2 and GND ASM 523501.
NOTE: The selector of the manual selector valve 2504MJ must stay in the CLOSE position during the fault isolation procedure.
   (1) If there is no 28 VDC:
  • Do a check for 28 VDC between:
    The RELAY (15MJ) connector A/X and GND ASM 523501.
     (a) If there is 28 VDC:
  • Do a check for 28 VDC between:
    The RELAY (15MJ) connector A/A2 and GND ASM 523501.
       1 If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between:
    The RELAY (15MJ) connector A/A2 and the CB (1MJ) ASM 523501.
       2 If there is 28 VDC:
  • Replace the RELAY (15MJ).
     (b) If there is no 28 VDC:
  • Do a check for 28 VDC between:
    The RELAY-TIME [6MJ] connector A/C1 and GND ASM 523501.
       1 If there is no 28 VDC:
  • Do a check for 28 VDC between:
    The RELAY-L/G POSITION, SYS 2 [12GB] connector A/D1 and A/D2 ASM 523501.
         a If there is 28 VDC:
  • Do a check for continuity:
    The RELAY-L/G POSITION, SYS 2 [12GB] connector A/D1 and A/D2 ASM 523501.
         b If there is continuity:
  • Do a check and repair the wiring as necessary between:
    The RELAY-TIME [6MJ] connector A/C1 and the RELAY-L/G POSITION, SYS 2 [12GB] connector A/D2 ASM 523501.
         c If there is no continuity:
  • Replace the RELAY-L/G POSITION, SYS 2 [12GB] .
         d If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between:
    The LGCIU-2 [5GA2] connector AA/8A and the RELAY-L/G POSITION, SYS 2 [12GB] connector A/D1 ASM 523501.
       2 If there is 28 VDC:
  • Do a check and repair the wiring as necessary between:
    The RELAY-TIME [6MJ] connector A/C1 and RELAY (15MJ) connector A/X ASM 523501.
   (2) If there is 28 VDC:
  • Do a check for 28 VDC between:
    The RELAY-TIME [6MJ] connector A/X1 and GND ASM 523501.
     (a) If there is 28 VDC:
  • Do a check and repair the wiring as necessary between:
    The RELAY-TIME [6MJ] connector A/X2 and GND ASM 523501.
       1 If the fault continues:
  • Replace the RELAY-TIME [6MJ] .
     (b) If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between:
    The RELAY-TIME [6MJ] connector A/X1 and the CB (1MJ) ASM 523501.
   (3) If the fault continues:
  • Do a check for a GND signal at:
    The LGCIU-2 [5GA2] connector AA/9A ASM 523501.
     (a) If there is no ground signal:
  • Do a check and repair the wiring between:
    The LGCIU-2 [5GA2] connector AA/9A and GND ASM 523501.
   (4) If the fault continues:
  • Do a check for 28 VDC at:
    The LGCIU-2 [5GA2] connector AA/7B and GND ASM 523501.
     (a) If there is no 28 VDC:
  • Do a check for continuity between:
    The MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connectors A/B and the LGCIU-2 [5GA2] connector AA/7B ASM 523501.
       1 If there is no continuity:
  • Do a check and repair the wiring as necessary between:
    The MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connectors A/B and LGCIU-2 [5GA2] connector AA/7B ASM 523501.
       2 If there is continuity:
  • Do a check for 28 VDC between:
    The MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connectors A/A and GND ASM 523501.
         a If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between:
    The MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connectors A/A and C/B-DOORS/CARGO [1MJ] ASM 523501.
    The MAN SEL VALVE-AFT CARGO DOOR [2504MJ] connectors A/C and GND ASM 523501.
   (5) If there is 28 VDC:
     (a) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
     (b) If there is 28 VDC:
   (6) If the fault continues:
  • Make sure that the clearance between the target and the proximity sensor ( SW-LOCKING SHAFT [12MJ] ) is correctly adjusted AMM 52-35-13-400-002.
     (a) If the fault continues:
   (7) If the fault continues:
   (8) If the fault continues:
Subtask 52-36-00-810-057-B
B. If the operation shows that the AFT cargo door does not close but the PACKAGE E-PUMP [3075GX] operates (fault in the door hydraulic system):
   (1) If the FWD cargo door moves:
     (a) If the fault continues:
   (2) If the FWD cargo door does not move:
     (a) If the AFT cargo door opens:
  • do a check for 28 VDC between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/A and A/B ASM 523501.
       1 If there is 28 VDC:
  • do a check for continuity between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/A and connector A/B ASM 523501.
         a If there is no continuity:
         b If there is continuity:
  • do a check and repair the wiring between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/A and GND ASM 523501.
       2 If there is no 28 VDC:
  • do a check and repair the wiring between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/B and the RELAY (13MJ) connector A/B3 ASM 523501
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/B and the RELAY (14MJ) connector A/B3 ASM 523501
    the RELAY (13MJ) connector A/B2 and the RELAY (15MJ) connector A/A2 ASM 523501
    the RELAY (14MJ) connector A/B2 and the RELAY (15MJ) connector A/A2 ASM 523501.
     (b) If the FWD cargo door does not open:
Subtask 52-36-00-810-069-A
C. If the AFT Cargo Door does not close fully:
   (1) Replace the MAN SEL VALVE-AFT CARGO DOOR [2504MJ] AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
   (2) If the fault continues:
     (a) Replace the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] AMM 52-36-12-000-001 and AMM 52-36-12-400-001.
   (3) If the fault continues:
     (a) Replace the ACTUATOR-AFT CARGO DOOR, FWD [2505MJ] AMM 52-36-18-000-001 and AMM 52-36-18-400-001.
   (4) If the fault continues:
     (a) Replace the ACTUATOR-AFT CARGO DOOR, AFT [2506MJ] AMM 52-36-18-000-001 and AMM 52-36-18-400-001.
   (5) If the fault continues:
     (a) Replace the VALVE-DOUBLE CHECK [3717GM] AMM 52-36-13-000-001 and AMM 52-36-13-400-001.
Subtask 52-36-00-869-054-A
D. Do this test as given in Para. 3.A. to make sure that the operation is correct.