W DOC AIRBUS | TSM A320F

Fault during the Opening Procedure of the FWD Cargo-Compartment Door


TASK 52-36-00-810-801-A
Fault during the Opening Procedure of the FWD Cargo-Compartment Door


1. Possible Causes
  • PACKAGE E-PUMP [3075GX]
  • RELAY (15MJ)
  • wiring
  • RELAY-TIME [6MJ]
  • RELAY-L/G POSITION, SYS 2 [12GB]
  • LGCIU-2 [5GA2]
  • MAN SEL VALVE-FWD CARGO DOOR [2501MJ]
  • SW-LOCKING SHAFT [5MJ]
  • 4VD
  • ACTUATOR-FWD CARGO DOOR, FWD [2502MJ]
  • ACTUATOR-FWD CARGO DOOR, AFT [2503MJ]
  • SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ]
  • RELAY (13MJ)
  • RELAY (14MJ)
  • VALVE-DOUBLE CHECK [3717GM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 32-31-00-810-802-A
LGCIU Fault
TSM TASK 32-31-00-810-834-A
Cargo Door (Fwd) Lockshaft Proximity Sensor Fault (5MJ)
ESPM 204423
ASM 292401
AMM 52-30-00-860-001
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
AMM 52-30-00-860-003
Open the FWD or Aft Cargo-Compartment Door with the Hand Pump
ASM 523501
AMM 52-35-13-400-002
Installation of the Proximity Switches
AMM 52-36-12-000-001
Removal of the Electro-Manual Selector Valve
AMM 52-36-12-400-001
Installation of the Electro-Manual Selector Valve
AMM 52-36-13-000-001
Removal of Double Check Valve
AMM 52-36-13-400-001
Installation of Double Check Valve
AMM 52-36-15-000-001
Removal of the Manual Selector Valve
AMM 52-36-15-400-001
Installation of the Manual Selector Valve
AMM 52-36-18-000-001
Removal of the Door Actuator
AMM 52-36-18-400-001
Installation of the Door Actuator
3. Fault Confirmation
Subtask 52-36-00-860-050-A
A. Aircraft Maintenance Configuration
   (1) Open the FWD cargo compartment door (referred to as cargo door) in the normal mode AMM 52-30-00-860-001.
NOTE: Make sure that a second person does not operate the aft cargo door.
   (2) Open the aft cargo door in the normal mode AMM 52-30-00-860-001.
NOTE: Make sure that a second person does not operate the FWD cargo door.
4. Fault Isolation
Subtask 52-36-00-810-050-D
A. If the fault confirmation gives that only the FWD cargo door does not open and the PACKAGE E-PUMP [3075GX] does not operate (fault in the door control system):
  • Do a check for 28 VDC between the RELAY (15MJ) connector A/A2 and GND
  • ASM 523501.
NOTE: The selector of the manual selector valve 2501MJ must stay in the OPEN position during the fault isolation procedure.
   (1) If there is no 28 VDC:
  • Do a check for 28 VDC between the RELAY (15MJ) connector A/X and GND
  • ASM 523501.
   (2) If there is 28 VDC:
  • Do a check for 28 VDC between the RELAY (15MJ) connector A/A1 and GND
  • ASM 523501.
   (3) If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between the RELAY (15MJ) connector A/A1 and the CB (1MJ)
  • ASM 523501.
   (4) If there is 28 VDC:
  • Replace the RELAY (15MJ).
   (5) If there is no 28 VDC:
     (a) Do a check for 28 VDC between the RELAY-TIME [6MJ] connector A/C1 and GND:
     (b) Do a check for 28 VDC between the RELAY-TIME [6MJ] connector A/A1 and GND:
   (6) If there is no 28 VDC:
  • Do a check for 28 VDC between the RELAY-L/G POSITION, SYS 2 [12GB] connector A/D1 and A/D2
  • ASM 523501.
   (7) If there is 28 VDC:
  • Do a check for continuity the RELAY-L/G POSITION, SYS 2 [12GB] connector A/D1 and A/D2
  • ASM 523501.
   (8) If there is continuity:
  • Do a check and repair the wiring as necessary between the RELAY-TIME [6MJ] connector A/C1 and the RELAY-L/G POSITION, SYS 2 [12GB] connector A/D2
  • ASM 523501.
   (9) If there is no continuity:
  • Replace the RELAY-L/G POSITION, SYS 2 [12GB]
   (10) If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between the LGCIU-2 [5GA2] connector AA/8A and the RELAY-L/G POSITION, SYS 2 [12GB] connector A/D1
  • ASM 523501.
   (11) If there is 28 VDC:
  • Do a check and repair the wiring as necessary between the RELAY-TIME [6MJ] connector A/C1 and RELAY (15MJ) connector A/X
  • ASM 523501.
   (12) If there is 28 VDC:
  • Do a check for 28 VDC between the RELAY-TIME [6MJ] connector A/X1 and GND
  • ASM 523501.
   (13) If there is 28 VDC:
  • Do a check and repair the wiring as necessary between the RELAY-TIME [6MJ] connector A/X2 and GND
  • ASM 523501.
   (14) If the fault continues:
  • Replace the RELAY-TIME [6MJ] .
   (15) If there is no 28 VDC:
  • Do a check and repair the wiring as necessary between the RELAY-TIME [6MJ] connector A/X1 and the CB (1MJ)
  • ASM 523501.
   (16) If the fault continues:
  • Do a check for a GND signal at the LGCIU-2 [5GA2] connector AA/9A
  • ASM 523501.
   (17) If the fault continues:
  • Do a check for 28 VDC between the LGCIU-2 [5GA2] connector AA/7A and GND
  • ASM 523501.
   (18) If there are no 28 VDC:
  • Do a check for continuity between the LGCIU-2 [5GA2] connector A/B and the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] connector AA/7A
  • ASM 523501.
   (19) If there is no continuity:
  • Do a check and repair the wiring as necessary between the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] connector A/B and the LGCIU-2 [5GA2] connector AA/7A
  • ASM 523501.
   (20) If there is continuity:
  • Do a check for 28 VDC between the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] connector A/A and GND
  • ASM 523501.
   (21) If there is no 28 VDC:
     (a) Do a check and repair the wiring as necessary between:
  • The MAN SEL VALVE-FWD CARGO DOOR [2501MJ] connector A/A and the CB (1MJ)
  • The MAN SEL VALVE-FWD CARGO DOOR [2501MJ] connector A/C and the GND ASM 523501.
   (22) If there is 28 VDC:
     (a) Replace the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
   (23) If there is 28 VDC:
   (24) If the fault continues:
  • Make sure that the clearance between the target and the proximity sensor ( SW-LOCKING SHAFT [5MJ] ) is correctly adjusted AMM 52-35-13-400-002.
   (25) If the fault continues:
   (26) If the fault continues:
   (27) If the fault continues:
Subtask 52-36-00-810-054-B
B. If the test shows that the FWD cargo door does not open but the PACKAGE E-PUMP [3075GX] operates (fault in the door hydraulic system):
   (1) If the aft cargo door moves:
     (a) If the fault continues:
   (2) If the aft cargo door does not move:
     (a) If the FWD cargo door opens:
  • do a check for 28 VDC between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/A and A/B ASM 523501.
       1 If there is 28 VDC:
  • do a check for continuity between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/B and connector A/A ASM 523501.
         a If there is no continuity:
         b If there is continuity:
  • do a check and repair the wiring between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/A and GND ASM 523501.
       2 If there is no 28 VDC:
  • do a check and repair the wiring between:
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/B and the RELAY (13MJ) connector A/B3 ASM 523501
    the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] connector A/B and the RELAY (14MJ) connector A/B3 ASM 523501
    the RELAY (13MJ) connector A/B2 and the RELAY (15MJ) connector A/A2 ASM 523501
    the RELAY (14MJ) connector A/B2 and the RELAY (15MJ) connector A/A2 ASM 523501.
     (b) If the FWD cargo door does not open:
Subtask 52-36-00-810-066-A
C. If the FWD Cargo Door does not open fully:
   (1) Replace the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
   (2) If the fault continues:
     (a) Replace the SEL VALVE-CARGO DOORS ELEC/MAN CTL [2500MJ] AMM 52-36-12-000-001 and AMM 52-36-12-400-001.
   (3) If the fault continues:
     (a) Replace the ACTUATOR-FWD CARGO DOOR, FWD [2502MJ] AMM 52-36-18-000-001 and AMM 52-36-18-400-001.
   (4) If the fault continues:
     (a) Replace the ACTUATOR-FWD CARGO DOOR, AFT [2503MJ] AMM 52-36-18-000-001 and AMM 52-36-18-400-001.
   (5) If the fault continues:
     (a) Replace the VALVE-DOUBLE CHECK [3717GM] AMM 52-36-13-000-001 and AMM 52-36-13-400-001.
Subtask 52-36-00-869-051-A
D. Do the test as given in Para. 3.A. to make sure that the operation is correct.
[Rev.8 from Aug 2018] 2026.04.04 04:34:51 UTC