Sensor Monitoring Fault at the FWD Cargo Compartment Door
TASK 52-31-00-810-801-A
Sensor Monitoring Fault at the FWD Cargo Compartment Door
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 52-31-00-710-050-A
Subtask 52-31-00-810-050-A ** ON A/C NOT FOR ALL
Subtask 52-31-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:51 UTC
Sensor Monitoring Fault at the FWD Cargo Compartment Door
1. Possible Causes
- PROX SWITCH
- PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV]
- wiring
- LGCIU-1 [5GA1]
- PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 32-31-00-810-830-A | Cargo Door (Fwd) Handle Proximity Sensor Fault (28WV) |
| TSM TASK 32-31-00-810-832-A | Cargo Door (Fwd) Safety Mechanism Proximity Sensor Fault (30WV) |
| ESPM 205500 | |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-36-00-740-008 | Access to the Parameter Call-Up Menus |
| ASM 315405 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 52-30-00-860-001 | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| AMM 52-30-00-860-002 | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| AMM 52-71-00-820-003 | Adjustment of the Proximity Switches of the Cargo Compartment Door Threshold |
| AMM 52-71-00-820-004 | Adjustment of the Proximity Switches of the Locking Handle of the Cargo Compartment Doors |
| AMM 52-71-12-000-002 | Removal of the Proximity Switches |
| AMM 52-71-12-400-002 | Installation of the Proximity Switches |
Subtask 52-31-00-710-050-A
A. Test
(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) Open and close the FWD Cargo-Compartment Door (referred to as cargo door) AMM 52-30-00-860-001 and AMM 52-30-00-860-002.
(3) Look for the fault indications at the door page of the lower ECAM DU.
4. Fault Isolation(1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) Open and close the FWD Cargo-Compartment Door (referred to as cargo door) AMM 52-30-00-860-001 and AMM 52-30-00-860-002.
(3) Look for the fault indications at the door page of the lower ECAM DU.
Subtask 52-31-00-810-050-A ** ON A/C NOT FOR ALL
A. When the cargo door is closed and locked and the door page of the lower ECAM DU shows the symbol for the cargo door and the maintenance message CARGO in amber:
(1) Do a check of the PROX SWITCH and the target:
(a) If a PROX SWITCH and/or a target is not clean:
1 Clean the PROX SWITCH and/or the target ESPM 205500.
(b) Do the test in the Para. Fault Confirmation.
(2) If the fault continues:
Subtask 52-31-00-810-050-B ** ON A/C NOT FOR ALL (1) Do a check of the PROX SWITCH and the target:
(a) If a PROX SWITCH and/or a target is not clean:
1 Clean the PROX SWITCH and/or the target ESPM 205500.
(b) Do the test in the Para. Fault Confirmation.
(2) If the fault continues:
- Get access to the parameter call-up menus AMM 31-36-00-740-008
- Enter this EQ/SYS/LAB/SDI/ parameter to the scratchpad:
6D/1/022/01 or 6D/2/022/10 - Look at the line "SSM DATABITS 28-11"
- Refer also to the specific parameter 1.022.01 or 2.022.10 of the LGCIU - ARINC 429 Output Data (Ref. AMM 32-61-00, P. Block 1).
- Make sure that the adjustment of the PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] is correct AMM 52-71-00-820-003.
- Replace the PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] AMM 52-71-12-000-002 and AMM 52-71-12-400-002.
- Do a check and repair the wiring between the:
PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] connector A/A and LGCIU-1 [5GA1] connector AA/6C,
PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] connector A/B and LGCIU-1 [5GA1] connector AA/6D. ASM 315405
- Make sure that the adjustment of the PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] is correct AMM 52-71-00-820-004.
- replace the PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] AMM 52-71-12-000-002 and AMM 52-71-12-400-002.
- Do a check and repair the wiring between the:
PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] connector A/A and LGCIU-1 [5GA1] connector AA/6G,
PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] connector A/B and LGCIU-1 [5GA1] connector AA/6H. ASM 315405
- Do the trouble shooting of the LGCIU-1 [5GA1] (Ref. TSM TASK 32-31-00-810-830) and (Ref. TSM TASK 32-31-00-810-832).
A. When the cargo door is closed and locked and the door page of the lower ECAM DU shows the symbol for the cargo door and the maintenance message CARGO in amber:
(1) Do a check of the PROX SWITCH and the target:
(a) If a PROX SWITCH and/or a target is not clean:
1 Clean the PROX SWITCH and/or the target ESPM 205500.
(b) Do the test in the Para. Fault Confirmation.
(2) If the fault continues:
Subtask 52-31-00-710-052-A (1) Do a check of the PROX SWITCH and the target:
(a) If a PROX SWITCH and/or a target is not clean:
1 Clean the PROX SWITCH and/or the target ESPM 205500.
(b) Do the test in the Para. Fault Confirmation.
(2) If the fault continues:
- Get access to the parameter call-up menus AMM 31-36-00-740-008
- Enter this EQ/SYS/LAB/SDI/ parameter to the scratchpad:
06D/1/022/01 or 06D/2/022/10 - Look at the line "SSM DATABITS 28-11"
- Refer also to the specific parameter 1.022.01 or 2.022.10 of the LGCIU - ARINC 429 Output Data (Ref. AMM 32-61-00, P. Block 1).
- Make sure that the adjustment of the PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] is correct AMM 52-71-00-820-003.
- Replace the PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] AMM 52-71-12-000-002 and AMM 52-71-12-400-002.
- Do a check and repair the wiring between the:
PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] connector A/A and LGCIU-1 [5GA1] connector AA/6C,
PROX SW-FRAME, FWD CARGO COMPT DOOR [30WV] connector A/B and LGCIU-1 [5GA1] connector AA/6D. ASM 315405
- Make sure that the adjustment of the PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] is correct AMM 52-71-00-820-004.
- Replace the PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] AMM 52-71-12-000-002 and AMM 52-71-12-400-002.
- Do a check and repair the wiring between the:
PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] connector A/A and LGCIU-1 [5GA1] connector AA/6G,
PROX SW-HANDLE, FWD CARGO COMPT DOOR [28WV] connector A/B and LGCIU-1 [5GA1] connector AA/6H. ASM 315405
- Do the trouble shooting of the LGCIU-1 [5GA1] (Ref. TSM TASK 32-31-00-810-830) and (Ref. TSM TASK 32-31-00-810-832).
B. Do the test as given in Para.3.A. to make sure that the operation is correct.
5. Close-upSubtask 52-31-00-860-050-A