Pressure Leakage on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-810-815-A
Pressure Leakage on the Door Damper and Emergency Operation Cylinder
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Fault Confirmation
Subtask 52-22-00-860-063-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-865-059-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:41 UTC
Pressure Leakage on the Door Damper and Emergency Operation Cylinder
1. Possible Causes
- seal of the pressure filling valve
- pressure filling valve
- door damper
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| No specific | OXYGEN LEAK DETECTION |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 52-22-00-010-001 | Opening of the Emergency Exit Doors from the Passenger Compartment |
| AMM 52-22-00-410-001 | Closing of the Emergency Exit Doors from the Passenger Compartment |
| AMM 52-22-00-614-002 | Charging of the Door Damper and Emergency Operation Cylinders at the Emergency Exit Doors |
| AMM 52-22-00-860-003 | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| AMM 52-22-00-860-004 | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
| AMM 52-22-00-860-005 | Replacement of the Charging Valve and Percussion Mechanism Seals |
| AMM 52-22-14-000-001 | Removal of the Door Damper and Emergency Operation Cylinder |
| AMM 52-22-14-400-001 | Installation of the Door Damper and Emergency Operation Cylinder |
Subtask 52-22-00-860-063-A ** ON A/C NOT FOR ALL
A. Job Set-up
(1) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the applicable emergency exit door.
(2) Open (but not fully) the applicable emergency exit door as necessary AMM 52-22-00-010-001.
(3) Do the special precautions before maintenance on the door damper and emergency operation cylinder (referred to as door damper) AMM 52-22-00-860-003.
Subtask 52-22-00-865-058-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the applicable emergency exit door.
(2) Open (but not fully) the applicable emergency exit door as necessary AMM 52-22-00-010-001.
(3) Do the special precautions before maintenance on the door damper and emergency operation cylinder (referred to as door damper) AMM 52-22-00-860-003.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 52-22-00-860-065-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU B/ESS | 153RH | G03 |
C. Leak Test of the Door Damper
(1) Charge the pressure accumulator of the door damper with the correct pressure AMM 52-22-00-614-002.
(2) Apply a solution of OXYGEN LEAK DETECTION or a WATER - SOAPY SOLUTION to the subsequent components to find an air leak:
4. Fault Isolation(1) Charge the pressure accumulator of the door damper with the correct pressure AMM 52-22-00-614-002.
(2) Apply a solution of OXYGEN LEAK DETECTION or a WATER - SOAPY SOLUTION to the subsequent components to find an air leak:
- between the striker housing and the housing assy (leak point 1)
- on the charging valve (leak point 2)
- between the pressure gage and the bottle assembly (leak point 3)
- on the vent hole of the bottle assembly (leak point 5)
- between the charging valve and the bottle assembly (leak point 6)
WARNING:
BEFORE YOU START WORK ON THE DOOR MAKE SURE THAT: - THE SLIDE CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED. - THE PERCUSSION LEVER OF THE DOOR DAMPER CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
Subtask 52-22-00-810-063-B ** ON A/C NOT FOR ALL A. If you find a sign of nitrogen leaks (bubbles), continue as follows:
(1) If you find a leak on leak point 3:
(a) If there are bubbles again:
(a) If there are bubbles:
5. Close-up(1) If you find a leak on leak point 3:
(a) If there are bubbles again:
- replace the seal of the pressure filling valve AMM 52-22-00-860-005 and do the leak test again.
(a) If there are bubbles:
- replace the pressure filling valve AMM 52-22-00-860-005 and do the leak test again.
- replace the door damper AMM 52-22-14-000-001 and AMM 52-22-14-400-001.
- replace the door damper AMM 52-22-14-000-001 and AMM 52-22-14-400-001.
- replace the door damper AMM 52-22-14-000-001 and AMM 52-22-14-400-001.
Subtask 52-22-00-865-059-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-22-00-860-064-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU B/ESS | 153RH | G03 |
B. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precautions after maintenance on the door damper AMM 52-22-00-860-004.
(3) Close the applicable door AMM 52-22-00-410-001.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precautions after maintenance on the door damper AMM 52-22-00-860-004.
(3) Close the applicable door AMM 52-22-00-410-001.

Leak Check Points on the Door Damper and Emergency Operation Cylinder