W DOC AIRBUS | TSM A320F

Water Seepage at the Emergency Exit Doors


TASK 52-22-00-810-810-A
Water Seepage at the Emergency Exit Doors


1. Possible Causes
  • sealing profile
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 52-22-00-010-001
Opening of the Emergency Exit Doors from the Passenger Compartment
AMM 52-22-00-860-003
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
AMM 52-22-00-860-004
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
AMM 52-22-18-300-001
Preventive Seepage Procedure
3. Fault Confirmation
Subtask 52-22-00-210-050-A ** ON A/C NOT FOR ALL
A. Visual Inspection
   (1) Open the applicable emergency exit door and make sure that the access platform is in position below the opened door AMM 52-22-00-010-001.
   (2) Make sure that the special precautions procedure on the door damper and emergency operation cylinder is done AMM 52-22-00-860-003.
   (3) Visually inspect the lower area of the sealing profile above the opened emergency exit door.
4. Fault Isolation
Subtask 52-22-00-810-058-A ** ON A/C NOT FOR ALL
A. If the sealing profile above the emergency exit door is moist:
5. Close-up
Subtask 52-22-00-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the special precautions procedure on the door damper and emergency operation cylinder is done AMM 52-22-00-860-004.
   (2) Close the applicable emergency exit door and remove the access platform AMM 52-22-00-010-001.
[Rev.8 from Aug 2018] 2026.04.04 04:34:50 UTC