Water Seepage at the Emergency Exit Doors
TASK 52-22-00-810-810-A
Water Seepage at the Emergency Exit Doors
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 52-22-00-210-050-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-810-058-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-860-054-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:50 UTC
Water Seepage at the Emergency Exit Doors
1. Possible Causes
- sealing profile
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 52-22-00-010-001 | Opening of the Emergency Exit Doors from the Passenger Compartment |
| AMM 52-22-00-860-003 | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| AMM 52-22-00-860-004 | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
| AMM 52-22-18-300-001 | Preventive Seepage Procedure |
Subtask 52-22-00-210-050-A ** ON A/C NOT FOR ALL
A. Visual Inspection
(1) Open the applicable emergency exit door and make sure that the access platform is in position below the opened door AMM 52-22-00-010-001.
(2) Make sure that the special precautions procedure on the door damper and emergency operation cylinder is done AMM 52-22-00-860-003.
(3) Visually inspect the lower area of the sealing profile above the opened emergency exit door.
4. Fault Isolation(1) Open the applicable emergency exit door and make sure that the access platform is in position below the opened door AMM 52-22-00-010-001.
(2) Make sure that the special precautions procedure on the door damper and emergency operation cylinder is done AMM 52-22-00-860-003.
(3) Visually inspect the lower area of the sealing profile above the opened emergency exit door.
Subtask 52-22-00-810-058-A ** ON A/C NOT FOR ALL
A. If the sealing profile above the emergency exit door is moist:
5. Close-up- do the preventive seepage procedure of the sealing profile AMM 52-22-18-300-001.
Subtask 52-22-00-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the special precautions procedure on the door damper and emergency operation cylinder is done AMM 52-22-00-860-004.
(2) Close the applicable emergency exit door and remove the access platform AMM 52-22-00-010-001.
(1) Make sure that the special precautions procedure on the door damper and emergency operation cylinder is done AMM 52-22-00-860-004.
(2) Close the applicable emergency exit door and remove the access platform AMM 52-22-00-010-001.