Disagree between the DOOR/OXY Page of the ECAM System and the locked RH FWD Emergency Exit Door
TASK 52-22-00-810-802-A
Disagree between the DOOR/OXY Page of the ECAM System and the locked RH FWD Emergency Exit Door
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 52-22-00-860-051-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-810-051-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-710-072-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:50 UTC
Disagree between the DOOR/OXY Page of the ECAM System and the locked RH FWD Emergency Exit Door
1. Possible Causes
- PROX SW-HOOK, R FWD EMER EXIT [59WV2]
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
- wiring
- C/B-EIS/SDAC1 AND 2/DOOR/DET/PAX [48WV]
- IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2]
- PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2]
- C/B-EIS/SLIDES/ARM AND WARN/GND [13WN]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| ASM 315405 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 52-22-00-410-001 | Closing of the Emergency Exit Doors from the Passenger Compartment |
| AMM 52-71-00-820-005 | Adjustment of the Proximity Switches of the Emergency Exits with the CHECKING TOOL-DOORS |
| AMM 52-71-00-820-007 | Adjustment of the Proximity Switches of the Emergency Exit Doors with the CHECKING TOOL-DOORS |
| AMM 52-71-13-000-003 | Removal of the Proximity Switches |
| AMM 52-71-13-400-003 | Installation of the Proximity Switches |
| AMM 52-73-22-000-003 | Removal of the CABIN PRESSURE Warning Light Panel of the Emergency Exit |
| AMM 52-73-22-400-003 | Installation of the CABIN PRESSURE Warning Light Panel of the Emergency Exit Door |
Subtask 52-22-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 52-22-00-865-051-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 52-22-00-710-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
C. Test
(1) Make sure that the RH FWD emergency exit door is closed and locked AMM 52-22-00-410-001.
(2) On the ECAM control panel:
4. Fault Isolation(1) Make sure that the RH FWD emergency exit door is closed and locked AMM 52-22-00-410-001.
(2) On the ECAM control panel:
- push the DOOR key to get the DOOR/OXY page.
Subtask 52-22-00-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives the amber EMER EXIT indication of the RH FWD emergency exit door:
5. Close-up- Do a check and adjust as necessary the PROX SW-HOOK, R FWD EMER EXIT [59WV2] AMM 52-71-00-820-005.
- Install the jumper wire between the PROX SW-HOOK, R FWD EMER EXIT [59WV2] connector A/C and A/B ASM 315405.
- Replace the PROX SW-HOOK, R FWD EMER EXIT [59WV2] AMM 52-71-13-000-003 and AMM 52-71-13-400-003.
- Remove the jumper wire.
- Remove the jumper wire.
- Do a check for a ground signal at the PROX SW-HOOK, R FWD EMER EXIT [59WV2] connector A/C ASM 315405.
- Do a check and repair the wiring between the PROX SW-HOOK, R FWD EMER EXIT [59WV2] connector A/B and the SDAC-1 [1WV1] or the SDAC-2 [1WV2] connector AA/11C ASM 315405.
- Do a check for 28 VDC between the:
the PROX SW-HOOK, R FWD EMER EXIT [59WV2] connector A/A and A/D ASM 315405.
- Replace the PROX SW-HOOK, R FWD EMER EXIT [59WV2] AMM 52-71-13-000-003 and AMM 52-71-13-400-003.
- The PROX SW-HOOK, R FWD EMER EXIT [59WV2] connector A/A and CB C/B-EIS/SDAC1 AND 2/DOOR/DET/PAX [48WV] , and the connector PROX SW-HOOK, R FWD EMER EXIT [59WV2] A/D and ground.
- Do a check for continuity between the IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] connectors A/F and A/G ASM 315405.
- Replace the IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] AMM 52-73-22-000-003 and AMM 52-73-22-400-003.
- Do a check and repair the wiring between:
The PROX SW-HOOK, R FWD EMER EXIT [59WV2] connector A/C and IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] connector A/G.
The PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] connector A/B and IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] connector A/F.
- Do a check and adjust as necessary the PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] AMM 52-71-00-820-007.
- Install the jumper wire between the PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] connector A/C and A/B ASM 315405.
- Replace the PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] AMM 52-71-13-000-003 and AMM 52-71-13-400-003.
- Remove the jumper wire.
- Remove the jumper wire.
- Do a check and repair the wiring between the PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] connector A/C and ground ASM 315405.
- Do a check for 28VDC between the PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] connector A/A and A/D ASM 315405.
- Do a check for a continuity between the IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] connectors A/S and A/A ASM 315405.
- Do a check and repair the wiring between
IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] connector A/A and CB PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] , C/B-EIS/SLIDES/ARM AND WARN/GND [13WN] A/A and IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] A/S, PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] .
- Replace the IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT [21WN2] AMM 52-73-22-000-003 and AMM 52-73-22-400-003.
- Replace the PROX SW-HANDLE FLAP, R FWD EMER EXIT [19WV2] AMM 52-71-13-000-003 and AMM 52-71-13-400-003.
Subtask 52-22-00-710-072-A ** ON A/C NOT FOR ALL
A. Do the test as given in para. 3