W DOC AIRBUS | TSM A320F

Sensor Monitoring Fault at the RH Passenger Compartment Emergency Exit


TASK 52-21-00-810-807-A
Sensor Monitoring Fault at the RH Passenger Compartment Emergency Exit


1. Possible Causes
  • PROX SW-HANDLE FLAP, R AFT EMER EXIT [21WV2]
  • wiring
  • IND LT-SLIDE ARMED, R EMER EXIT [2WN2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 315405
AMM 31-60-00-860-001
EIS Start Procedure
AMM 52-71-13-000-001
Removal of the Proximity Switches
AMM 52-71-13-400-001
Installation of the Proximity Switches
AMM 52-73-21-000-003
Removal of the SLIDE ARMED Indicator-Light of the Emergency Exit
AMM 52-73-21-400-003
Installation of the SLIDE ARMED Indicator-Light of the Emergency Exit
3. Fault Confirmation
Subtask 52-21-00-710-061-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
   (2) Remove and install the cover flap of the RH emergency exit hatch (refererd to as hatch).
   (3) Look for the fault indications at the door page of the lower ECAM DU.
4. Fault Isolation
Subtask 52-21-00-810-058-A ** ON A/C NOT FOR ALL
A. When the cover flap is correctly installed and the door page of the lower ECAM DU shows the symbol for the hatch and the message EMER EXIT in amber:
   (1) If the fault continues:
  • make an electrical connection between the:
    PROX SW-HANDLE FLAP, R AFT EMER EXIT [21WV2] connectors A/A and A/B ASM 315405.
     (a) If the message EMER EXIT goes off and the symbol for the hatch changes to green:
     (b) If the fault continues:
  • do a check for 28 VDC between the:
    PROX SW-HANDLE FLAP, R AFT EMER EXIT [21WV2] connectors A/A and A/C ASM 315405.
       1 If there is 28 VDC:
  • do a check and repair the wiring between:
    the PROX SW-HANDLE FLAP, R AFT EMER EXIT [21WV2] connector A/B and the IND LT-SLIDE ARMED, R EMER EXIT [2WN2] connector A/E ASM 315405.
       2 If there is no 28 VDC:
  • do a check and repair the wiring between the:
    PROX SW-HANDLE FLAP, R AFT EMER EXIT [21WV2] connector A/A and the IND LT-SLIDE ARMED, R EMER EXIT [2WN2] connector A/R ASM 315405.
    PROX SW-HANDLE FLAP, R AFT EMER EXIT [21WV2] connector A/C and ground ASM 315405.
     (c) If the fault continues:
Subtask 52-21-00-710-062-A ** ON A/C NOT FOR ALL
B. Do a test as given in Para. 3.A. to make sure that the operation is correct.
5. Close-up
Subtask 52-21-00-860-055-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:34:49 UTC