EGT TCPLE Rake 1 Fault (131-9(A))


TASK 49-70-00-810-817-A
EGT TCPLE Rake 1 Fault (131-9(A))


1. Possible Causes
  • EGT1 SENSOR SHOWS OUT OF RANGE LOW
  • EGT1 SENSOR DISAGREES WITH EGT2 SENSOR > 66C
  • damage/contamination of the electrical connections
  • EGT 1 THERMOCOUPLE
  • aircraft wiring
  • EGT TCPLE RAKE (8057KM1)
  • ELECTRONIC CONTROL BOX [59KD]
  • EGT 2 THERMOCOUPLE
  • PRIMARY FUEL-NOZZLE and MANIFOLD
  • SECONDARY FUEL-NOZZLE and MANIFOLD
  • EGT TCPLE RAKE (8057KM2)
  • PRIMARY FUEL-NOZZLE and MANIFOLD (8020KM)
  • SECONDARY FUEL-NOZZLE and MANIFOLD (8021KM)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
MULTIMETER - STANDARD
 B. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 49-70-00-810-818-A
EGT TCPLE Rake 2 Fault (131-9(A))
AMM 49-00-00-860-008
APU Start by External Power
AMM 49-31-41-000-003
Removal of the Primary and Secondary Fuel-Nozzle (131-9(A))
AMM 49-31-41-400-003
Installation of the Primary and Secondary Fuel- Nozzle (131-9(A))
AMM 49-31-42-000-004
Removal of the Primary and Secondary Fuel-Manifold (131-9(A))
AMM 49-31-42-400-006
Installation of the Primary and Secondary Fuel-Manifold (131-9(A))
ASM 496101
AMM 49-61-34-000-003
Removal of the Electronic Control Box (ECB) (131-9(A))
AMM 49-61-34-400-003
Installation of the Electronic Control Box (ECB) (131-9(A))
AMM 49-72-15-000-002
Removal of the Thermocouples (131-9(A))
AMM 49-72-15-400-003
Installation of the Thermocouples (131-9(A))
3. Fault Confirmation
Subtask 49-70-00-710-080-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
   (1) Put the APU MASTER SW to the ON position.
   (2) Get access to the APU LAST LEG/PREVIOUS LEG report.
   (3) Push the '>'-key adjacent to the related CFDS failure message.
   (4) If the MCDU menu shows:
EGT1 SENSOR SHOWS OUT OF RANGE LOW

  • do the Fault Confirmation that follows:
     (a) Get access to the APU GND SCANNING menu.
   (5) If the MCDU menu shows:
EGT1 SENSOR DISAGREES WITH EGT2 SENSOR > 66C

  • do the Fault Confirmation that follows:
     (a) Start the APU and apply Electrical Load and Bleed Air AMM 49-00-00-860-008.
     (b) Get access to the APU GND SCANNING menu.
4. Fault Isolation
Subtask 49-70-00-810-065-A ** ON A/C NOT FOR ALL
A. If the APU GND SCANNING menu gives the maintenance message:

EGT TCPLE RAKE 1

associated with Fault Code Number (FCN) 42

  • do a check for damage/contamination of the electrical connections of the EGT 1 THERMOCOUPLE.
   (1) If the electrical connection of the EGT 1 THERMOCOUPLE is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connections of the EGT 1 THERMOCOUPLE is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across the terminals chromel and alumel of the EGT 1 THERMOCOUPLE.
     (a) If the resistance is >20 Ohms:
     (b) If the resistance is < 20 Ohms:
  • do a check of the aircraft wiring from the ECB (59KD) AB/A6,A7 to the EGT 1 THERMOCOUPLE terminals chromel/alumel ASM 496101.
       1 If the fault continues:
Subtask 49-70-00-810-066-A ** ON A/C NOT FOR ALL
B. If the APU GND SCANNING menu gives the maintenance message:

EGT TCPLE RAKE 1

associated with Fault Code Number (FCN) 43

  • do a check for damage/contamination of the electrical connections of the EGT 1 THERMOCOUPLE.
   (1) If the electrical connection of the EGT 1 THERMOCOUPLE is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connections of the EGT 1 THERMOCOUPLE is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across the terminals:
    chromel and alumel of the EGT 1 THERMOCOUPLE; required value < 20 Ohms
    and
    chromel and grounded EGT 1 mount flange; required value > 100 kOhms
    and
    alumel and grounded EGT 1 mount flange; required value > 100 kOhms.
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • do a check of the aircraft wiring from the ECB (59KD) AB/A6,A7 to the EGT 1 THERMOCOUPLE terminals chromel/alumel ASM 496101.
       1 If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
Subtask 49-70-00-810-065-B ** ON A/C NOT FOR ALL
C. If the APU GND SCANNING menu gives the maintenance message:

EGT TCPLE RAKE (8057KM1)

associated with Fault Code Number (FCN) 42

  • do a check for damage/contamination of the electrical connections of the EGT TCPLE RAKE (8057KM1)
   (1) If the electrical connection of the EGT TCPLE RAKE (8057KM1) is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connections of the EGT TCPLE RAKE (8057KM1) are OK:
  • use a MULTIMETER - STANDARD to do a resistance check across the terminals chromel and alumel of the EGT TCPLE RAKE (8057KM1).
     (a) If the resistance is >20 Ohms:
     (b) If the resistance is < 20 Ohms:
  • do a check of the aircraft wiring from the ECB (59KD) AB/A6,A7 to the EGT TCPLE RAKE (8057KM1) terminals chromel/alumel ASM 496101.
       1 If the fault continues:
Subtask 49-70-00-810-066-B ** ON A/C NOT FOR ALL
D. If the APU GND SCANNING menu gives the maintenance message:

EGT TCPLE RAKE (8057KM1)

associated with Fault Code Number (FCN) 43

  • do a check for damage/contamination of the electrical connections of the EGT TCPLE RAKE (8057KM1).
   (1) If the electrical connection of the EGT TCPLE RAKE (8057KM1) is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connections of the EGT TCPLE RAKE (8057KM1) is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across the terminals:
    chromel and alumel of the EGT 1 THERMOCOUPLE; required value < 20 Ohms
    and
    chromel and grounded EGT 1 mount flange; required value > 100 kOhms
    and
    alumel and grounded EGT 1 mount flange; required value > 100 kOhms.
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • do a check of the aircraft wiring from the ECB (59KD) AB/A6,A7 to the EGT TCPLE RAKE (8057KM1) terminals chromel/alumel ASM 496101.
       1 If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
Subtask 49-70-00-710-081-A ** ON A/C NOT FOR ALL
E. Do the test given in Para. 3.