APU Indications on the ECAM after APU Usual Shutdown
TASK 49-61-00-810-816-A
APU Indications on the ECAM after APU Usual Shutdown
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 49-61-00-710-078-A ** ON A/C NOT FOR ALL
Subtask 49-61-00-810-074-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:41 UTC
APU Indications on the ECAM after APU Usual Shutdown
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 496101 | |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-61-00-710-078-A ** ON A/C NOT FOR ALL
A. Test
(1) On overhead panel 25VU, push the APU MASTER SW P/BSW (the ON legend goes on).
(2) On the lower ECAM display unit, select the APU page.
(3) Make sure that the APU indications on the APU page are correctly shown:
(5) On the lower ECAM display unit, when the FLAP OPEN message goes out of view, examine the APU indications on the APU page.
(a) If there are no APU indications and no EGT value is shown, no maintenance procedure is necessary.
(b) If there are APU indications and the EGT value is shown, the fault is confirmed.
4. Fault Isolation(1) On overhead panel 25VU, push the APU MASTER SW P/BSW (the ON legend goes on).
(2) On the lower ECAM display unit, select the APU page.
(3) Make sure that the APU indications on the APU page are correctly shown:
- The N% indication is 0%.
- The EGT value agrees with the ambient temperature.
- The FLAP OPEN message is shown in green color when the air intake flap is fully open.
(5) On the lower ECAM display unit, when the FLAP OPEN message goes out of view, examine the APU indications on the APU page.
(a) If there are no APU indications and no EGT value is shown, no maintenance procedure is necessary.
(b) If there are APU indications and the EGT value is shown, the fault is confirmed.
Subtask 49-61-00-810-074-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
(1) Do a check for 28VDC at pin AC/7 of the ECB ASM 496101
(a) If there is 28VDC, replace the RELAY-APU MAIN CTL [4KD] .
Subtask 49-61-00-810-075-A ** ON A/C NOT FOR ALL (1) Do a check for 28VDC at pin AC/7 of the ECB ASM 496101
(a) If there is 28VDC, replace the RELAY-APU MAIN CTL [4KD] .
B. If the fault continues:
(1) Replace the P/BSW-APU/MASTER SW [14KD] .
(2) Make sure that APU MASTER SW P/BSW is released (the ON legend is off).
Subtask 49-61-00-810-076-A ** ON A/C NOT FOR ALL (1) Replace the P/BSW-APU/MASTER SW [14KD] .
(2) Make sure that APU MASTER SW P/BSW is released (the ON legend is off).
C. If the fault continues:
(1) Replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
(1) Replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.