W DOC AIRBUS | TSM A320F

Incorrect Pin Coding (APS 3200)


TASK 49-61-00-810-805-A
Incorrect Pin Coding (APS 3200)


1. Possible Causes
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ASM 496101
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-61-00-710-058-A ** ON A/C NOT FOR ALL
A. Cycle the APU Master SW p/bsw 14KD to perform the Power-Up Test of the ECB.
NOTE: The Master SW ON state must be active for at least 10 seconds.
4. Fault Isolation
Subtask 49-61-00-810-054-B ** ON A/C NOT FOR ALL
A. If the APU Class 3 Faults Page gives the maintenance message:


WRG: ACFT TYPE PIN PROG / ECB (59KD):
Fault Code Number: 124


  • do a check and make sure that the two A321 IDENTIFICATION signals at the ECB (59KD) AB/A12, A13 ASM 496101 are the same.
   (1) If the two A321 IDENTIFICATION signals are not the same:
     (a) If the fault continues:
   (2) If the two A321 IDENTIFICATION are the same:
Subtask 49-61-00-710-059-B ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:40 UTC