Incorrect Pin Coding (APS 3200)
TASK 49-61-00-810-805-A
Incorrect Pin Coding (APS 3200)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-61-00-710-058-A ** ON A/C NOT FOR ALL
Subtask 49-61-00-810-054-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:40 UTC
Incorrect Pin Coding (APS 3200)
1. Possible Causes
- wiring
- ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2052210 | |
| ESPM 2053210 | |
| ASM 496101 | |
| AMM 49-61-34-000-002 | Removal of the Electronic Control Box (ECB) (APS 3200) |
| AMM 49-61-34-400-002 | Installation of the Electronic Control Box (ECB) (APS 3200) |
Subtask 49-61-00-710-058-A ** ON A/C NOT FOR ALL
A. Cycle the APU Master SW p/bsw 14KD to perform the Power-Up Test of the ECB.
4. Fault IsolationNOTE: The Master SW ON state must be active for at least 10 seconds.
Subtask 49-61-00-810-054-B ** ON A/C NOT FOR ALL
A. If the APU Class 3 Faults Page gives the maintenance message:
WRG: ACFT TYPE PIN PROG / ECB (59KD):
Fault Code Number: 124
Subtask 49-61-00-710-059-B ** ON A/C NOT FOR ALL WRG: ACFT TYPE PIN PROG / ECB (59KD):
Fault Code Number: 124
- do a check and make sure that the two A321 IDENTIFICATION signals at the ECB (59KD) AB/A12, A13 ASM 496101 are the same.
- do a check and repair the wiring to the ECB (59KD) AB/A12, A13 ASM 496101 ESPM 2052210 ESPM 2053210.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
B. Do the test given in Para. 3.