APU Inlet-Temperature (T2) Sensor Fault (131-9(A))
TASK 49-20-00-810-803-A
APU Inlet-Temperature (T2) Sensor Fault (131-9(A))
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 49-20-00-710-054-A ** ON A/C NOT FOR ALL
Subtask 49-20-00-810-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:39 UTC
APU Inlet-Temperature (T2) Sensor Fault (131-9(A))
1. Possible Causes
- INLET TEMP SENSOR SHOWS OUT OF RANGE HIGH
- INLET TEMP SENSOR SHOWS OUT OF RANGE LOW
damage/contamination of electrical connector P6 INLET TEMPERATURE SENSOR (P6) - aircraft wiring
- ELECTRONIC CONTROL BOX [59KD]
INLET TEMPERATURE SENSOR (8010KM) INLET TEMPERATURE SENSOR (P6) INLET TEMPERATURE SENSOR (8010KM)
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-23-14-000-001 | Removal of the Sensor-APU Inlet Temperature (131-9(A)) |
| AMM 49-23-14-400-001 | Installation of the Sensor-APU Inlet Temperature (131-9(A)) |
| ASM 496102 | |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-20-00-710-054-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU LAST LEG/PREVIOUS LEG report.
(3) Push the '>' adjacent to the related CFDS failure message:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU LAST LEG/PREVIOUS LEG report.
(3) Push the '>' adjacent to the related CFDS failure message:
- the MCDU menu shows
INLET TEMP SENSOR SHOWS OUT OF RANGE HIGH
or
INLET TEMP SENSOR SHOWS OUT OF RANGE LOW
Subtask 49-20-00-810-052-A ** ON A/C NOT FOR ALL
A. If the APU GND SCANNING menu gives the maintenance message:
INLET TEMP SENSOR P6
associated with Fault Code Number (FCN) 57
Subtask 49-20-00-810-053-A ** ON A/C NOT FOR ALL INLET TEMP SENSOR P6
associated with Fault Code Number (FCN) 57
- do a check for
damage/contamination of electrical connector P6 of the INLET TEMPERATURE SENSOR (P6).
- do a repair/cleaning.
- use a MULTIMETER - STANDARD to do a resistance check across pin A and pin B of the INLET TEMPERATURE SENSOR (P6).
- replace the
INLET TEMPERATURE SENSOR (P6) AMM 49-23-14-000-001 and AMM 49-23-14-400-001.
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/H4,H2 to the INLET TEMPERATURE SENSOR (P6) P6/A,B ASM 496102.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. If the APU GND SCANNING menu gives the maintenance message:
INLET TEMP SENSOR P6
associated with Fault Code Number (FCN) 58
Subtask 49-20-00-810-052-B ** ON A/C NOT FOR ALL INLET TEMP SENSOR P6
associated with Fault Code Number (FCN) 58
- do a check for
damage/contamination of electrical connector P6 of the INLET TEMPERATURE SENSOR (P6).
- do a repair/cleaning.
- use a MULTIMETER - STANDARD to do a resistance check across pin A and pin B of the INLET TEMPERATURE SENSOR (P6).
- replace the
INLET TEMPERATURE SENSOR (P6) AMM 49-23-14-000-001 and AMM 49-23-14-400-001.
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/H4,H3 to the INLET TEMPERATURE SENSOR (P6) P6/A,B ASM 496102.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
C. If the APU GND SCANNING menu gives the maintenance message:
INLET TEMP SENSOR (8010KM)
associated with Fault Code Number (FCN) 57
Subtask 49-20-00-810-053-B ** ON A/C NOT FOR ALL INLET TEMP SENSOR (8010KM)
associated with Fault Code Number (FCN) 57
- do a check for
damage/contamination of electrical connector P6 of the INLET TEMPERATURE SENSOR (8010KM)
- do a repair/cleaning.
- use a MULTIMETER - STANDARD to do a resistance check across pin A and pin B of the INLET TEMPERATURE SENSOR (P6).
- replace the
INLET TEMPERATURE SENSOR (8010KM) AMM 49-23-14-000-001 and AMM 49-23-14-400-001.
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/H4,H2 to the INLET TEMPERATURE SENSOR (8010KM) P6/A,B ASM 496102.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
D. If the APU GND SCANNING menu gives the maintenance message:
INLET TEMP SENSOR (8010KM)
associated with Fault Code Number (FCN) 58
Subtask 49-20-00-710-055-A ** ON A/C NOT FOR ALL INLET TEMP SENSOR (8010KM)
associated with Fault Code Number (FCN) 58
- do a check for
damage/contamination of electrical connector P6 of the INLET TEMPERATURE SENSOR (8010KM)
- do a repair/cleaning.
- use a MULTIMETER - STANDARD to do a resistance check across pin A and pin B of the INLET TEMPERATURE SENSOR (P6).
- replace the
INLET TEMPERATURE SENSOR (8010KM) AMM 49-23-14-000-001 and AMM 49-23-14-400-001.
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/H4,H3 to the INLET TEMPERATURE SENSOR (8010KM) P6/A,B ASM 496102.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
E. Do a check of the APU GND SCANNING menu.