W DOC AIRBUS | TSM A320F

APU Audible Surge (APS 3200)


TASK 49-00-81-810-901-A
APU Audible Surge (APS 3200)


1. Possible Causes
  • APU air inlet
  • Magnetic Drain Plug (8077KM)
  • CHECK VALVE-APU BLEED [7260HM]
  • APU [4005KM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-12-51-200-001
Remove and Check Auxiliary Power Unit Bleed Check-Valve for Condition
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-11-11-000-003
Removal of the Power Plant (APU) (APS 3200)
AMM 49-11-11-400-003
Installation of the Power Plant (APU) (APS 3200)
AMM 49-16-00-210-805
General Visual Inspection of the APU Air Inlet Plenum and APU Air Intake (APS 3200)
AMM 49-16-42-000-002
Removal of the Air Intake Duct (APS 3200)
AMM 49-16-42-400-002
Installation of the Air Intake Duct (APS 3200)
AMM 49-16-48-000-003
Removal of the Lower Inlet-Plenum (APS 3200)
AMM 49-16-48-400-002
Installation of the Lower Inlet-Plenum (APS 3200)
AMM 49-20-00-290-001
APU Power Plant Borescope Inspection (APS 3200)
AMM 49-91-42-200-003
Inspection of the Magnetic Drain Plug (APS 3200)
3. Fault Confirmation
Subtask 49-00-81-710-262-A ** ON A/C NOT FOR ALL
A. Not applicable
4. Fault Isolation
Subtask 49-00-81-810-187-A ** ON A/C NOT FOR ALL
A. If there is an APU audible surge:
   (1) Check the CFDS for the fault messages that follow:
  • LC SURGE- BLEED CTL VLV (8051KM)
  • LC SURGE AND BCV - BLEED CTL VLV (8051KM)
  • OSCILLATING LC SURGE AND BLEED VLV.FAILED OPEN - BLEED CTL VLV (8051KM)
  • OSCILLATING LC SURGE BLD FLOW XDCR (8039KM)/BLD CTL VLV (8051KM)
     (a) If a fault message shows:
  • Do the related troubleshooting procedure.
     (b) If no fault message shows:
       1 Do a visual inspection of the APU air inlet for airflow blockage, FOD/DOD, plenum splitter loose and/or detachments AMM 49-16-00-210-805.
Subtask 49-00-81-810-188-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do a check of the Magnetic Drain Plug (8077KM) for debris AMM 49-91-42-200-003.
Subtask 49-00-81-810-195-A ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) Do a check of the CHECK VALVE-APU BLEED [7260HM] AMM 36-12-51-200-001.
Subtask 49-00-81-810-196-A ** ON A/C NOT FOR ALL
D. If the fault continues:
   (1) Do a borescope inspection of the Power Section Impeller and Diffuser AMM 49-20-00-290-001.
Subtask 49-00-81-810-197-A ** ON A/C NOT FOR ALL
E. If the fault continues:
   (1) Do the operational test of the APU AMM 49-00-00-710-008.
     (a) If there is an audible APU surge without a fault triggered:
     (b) If there is an audible APU surge with a fault message triggered:
  • Do the related troubleshooting procedure.
[Rev.8 from Aug 2018] 2026.04.04 04:34:31 UTC