APU EGT indication replaced by amber XX (131-9(A))
TASK 49-00-81-810-895-A
APU EGT indication replaced by amber XX (131-9(A))
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-240-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-160-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:38 UTC
APU EGT indication replaced by amber XX (131-9(A))
1. Possible Causes
- ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-00-00-710-010 | Operational Test of the APU |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-240-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-010.
(1) Do a check of the APU EGT indication on the lower ECAM DU (APU Page).
4. Fault Isolation(1) Do a check of the APU EGT indication on the lower ECAM DU (APU Page).
Subtask 49-00-81-810-160-A ** ON A/C NOT FOR ALL
A. If the APU EGT indication is replaced by amber XX:
Subtask 49-00-81-710-241-A ** ON A/C NOT FOR ALL - replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do the test given in Para. 3.