APU Bleed Control Valve indication replaced by amber XX (131-9(A))
TASK 49-00-81-810-893-A
APU Bleed Control Valve indication replaced by amber XX (131-9(A))
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-236-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-158-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:38 UTC
APU Bleed Control Valve indication replaced by amber XX (131-9(A))
1. Possible Causes
Load Control Valve (8050KM) - ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 49-00-81-810-864-A | "LCV-OPEN"- Signal Fault (131-9(A)) |
| AMM 31-32-00-860-001 | Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page |
| AMM 49-00-00-710-010 | Operational Test of the APU |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-236-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-010.
(1) Do a check of the APU Bleed Control-Valve indication on the lower ECAM DU (APU Page).
(2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST AMM 31-32-00-860-001.
4. Fault Isolation(1) Do a check of the APU Bleed Control-Valve indication on the lower ECAM DU (APU Page).
(2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST AMM 31-32-00-860-001.
Subtask 49-00-81-810-158-A ** ON A/C NOT FOR ALL
A. Maintenance Action
(1) If there is a CLASS 2 Fault Message
WRG: APU LOAD VALVE
with the LRU TROUBLE SHOOT DATA menu information:
LOAD VALVE OPEN SIGNAL SHOWS CIRCUIT FAILURE
Fault Code Number: 138
and the Bleed Control Valve indication is replaced by amber XX:
Subtask 49-00-81-710-237-A ** ON A/C NOT FOR ALL (1) If there is a CLASS 2 Fault Message
WRG: APU LOAD VALVE
with the LRU TROUBLE SHOOT DATA menu information:
LOAD VALVE OPEN SIGNAL SHOWS CIRCUIT FAILURE
Fault Code Number: 138
and the Bleed Control Valve indication is replaced by amber XX:
- do the trouble shooting of the
Load Control Valve (8050KM) (Ref. TSM TASK 49-00-81-810-864).
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do the test given in Para. 3.