Check IGV Assembly / IGV Actuator (8014KM), Bleed Shut Off due to high temperature
TASK 49-00-81-810-887-A
Check IGV Assembly / IGV Actuator (8014KM), Bleed Shut Off due to high temperature
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-224-B ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-152-B ** ON A/C NOT FOR ALL
Subtask 49-00-81-710-225-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:38 UTC
Check IGV Assembly / IGV Actuator (8014KM), Bleed Shut Off due to high temperature
1. Possible Causes
- Bleed Shut Off due to high temperature
damage/leakage of the fuel supply and return lines of the IGV ACTUATOR (8014KM) IGV ACTUATOR (8014KM) - APU [4005KM]
- damage of the IGV ACTUATOR linkage and the IGV assembly and the IGV actuator
damage/contamination of the electrical connector P21 of the IGV ACTUATOR (8014KM)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-00-00-860-008 | APU Start by External Power |
| AMM 49-11-11-000-004 | Removal of the Power Plant (APU) (131-9(A)) |
| AMM 49-11-11-400-004 | Installation of the Power Plant (APU) (131-9(A)) |
| AMM 49-23-51-000-004 | Removal of the Inlet Guide Vane - Actuator (131-9(A)) |
| AMM 49-23-51-400-004 | Installation of the Inlet Guide Vane - Actuator (131-9(A)) |
| ASM 496104 | |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-224-B ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the LAST LEG report.
(3) Push the '>' adjacent to LRU DATA:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the LAST LEG report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
Bleed Shut Off due to high temperature
Subtask 49-00-81-810-152-B ** ON A/C NOT FOR ALL
A. If the LAST LEG report gives the maintenance message:
CHECK IGV ASSEMBLY/IGV ACTUATOR (8014KM)
associated with Fault Code Number (FCN) 90
Subtask 49-00-81-810-190-B ** ON A/C NOT FOR ALL CHECK IGV ASSEMBLY/IGV ACTUATOR (8014KM)
associated with Fault Code Number (FCN) 90
- do a check for
damage/leakage of the fuel supply and return lines of the IGV ACTUATOR (8014KM) .
- do a repair
- remove the
IGV ACTUATOR (8014KM) from the APU [4005KM] AMM 49-23-51-000-004. - do a check for damage of the IGV ACTUATOR linkage and the IGV assembly and the IGV actuator .
- . make sure that the IGV has a travel range of 1 -0.01 in. or +0.01 in. (25.400 -0.254 mm or +0.254 mm).
- . measure the force of the IGV movement.
- replace the
IGV ACTUATOR (8014KM) AMM 49-23-51-400-004.
- replace the APU [4005KM] AMM 49-11-11-000-004 and AMM 49-11-11-400-004.
B. If the LAST LEG report gives the maintenance message:
CHECK IGV ASSEMBLY/IGV ACTUATOR (8014KM)
associated with Fault Code Number (FCN) 83
5. Close-upCHECK IGV ASSEMBLY/IGV ACTUATOR (8014KM)
associated with Fault Code Number (FCN) 83
- do a check for
damage/leakage of the fuel supply and return lines of the IGV ACTUATOR (8014KM) .
- do a repair
- remove the
IGV ACTUATOR (8014KM) from the APU [4005KM] AMM 49-23-51-000-004. - do a check for damage of the IGV ACTUATOR linkage and the IGV assembly and the IGV actuator .
- . make sure that the IGV has a travel range of 1 -0.01 in. or +0.01 in. (25.400 -0.254 mm or +0.254 mm).
- . measure the force of the IGV movement.
- do a check for
damage/contamination of the electrical connector P21 of the IGV ACTUATOR (8014KM) .
- do a repair/cleaning.
- use a multimeter to do the resistance check across pin 4 and pin 10 of the IGV ACTUATOR (P21).
- replace the
IGV ACTUATOR (8014KM) AMM 49-23-51-400-004.
- do a check of the aircraft wiring from the ECB (59KD) AB/G8 to the IGV ACTUATOR (8014KM) P21/4 ASM 496104.
- replace the ECB (59KD) AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
- replace the APU [4005KM] AMM 49-11-11-000-004 and AMM 49-11-11-400-004.
Subtask 49-00-81-710-225-B ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.