W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - OVERSPEED, Speed Sensors Failures (APS 3200)


TASK 49-00-81-810-883-A
APU AUTO SHUT DOWN - OVERSPEED, Speed Sensors Failures (APS 3200)


1. Possible Causes
  • SPEED SENSOR 1 (8060KM1)
  • SPEED SENSOR 2 (8060KM2)
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
AMM 49-71-13-000-002
Removal of the Speed Sensor (APS 3200)
AMM 49-71-13-400-002
Installation of the Speed Sensor (APS 3200)
3. Fault Confirmation
Subtask 49-00-81-710-216-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-81-810-148-A ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


SPD SNSR1 (8060KM1) AND SPD SNSR2 (8060KM2)
Fault Code Number: 068


NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERSPEED - SPD SNSR1 (8060KM1) AND SPD SNSR2 (8060KM2)
APU Auto Shut Down Fault Code Number: 068


   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
Subtask 49-00-81-710-217-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:31 UTC