W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - NO ACCELERATION, APU Fuel Supply Failure (APS 3200)


TASK 49-00-81-810-880-A
APU AUTO SHUT DOWN - NO ACCELERATION, APU Fuel Supply Failure (APS 3200)


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-22-00-810-801-A
APU Fuel System - Low Pressure
AMM 49-00-00-710-008
Operational Test of the APU
3. Fault Confirmation
Subtask 49-00-81-710-210-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-81-810-145-A ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


CHECK APU FUEL SUPPLY:


NOTE: The APU SHUTDOWNS report gives the maintenance message:
NO ACCELERATION - CHECK APU FUEL SUPPLY
APU Auto Shut Down Fault Code Number: 052


Subtask 49-00-81-710-211-A ** ON A/C NOT FOR ALL
B. Not Applicable.
[Rev.8 from Aug 2018] 2026.04.04 04:34:31 UTC