W DOC AIRBUS | TSM A320F

Bleed Valve Open Indication (APS 3200)


TASK 49-00-81-810-878-A
Bleed Valve Open Indication (APS 3200)


1. Possible Causes
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
AMM 49-00-00-710-008
Operational Test of the APU
ASM 496101
3. Fault Confirmation
Subtask 49-00-81-710-206-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-81-810-143-A ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


WRG: ECB PIN AB-H8:
Fault Code Number: 022


Subtask 49-00-81-710-207-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:31 UTC