ECB internal Fault (131-9(A))
TASK 49-00-81-810-866-A
ECB internal Fault (131-9(A))
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-082-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-069-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:37 UTC
ECB internal Fault (131-9(A))
1. Possible Causes
- ECB INTERNAL FAILURE
- ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-082-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU LAST LEG/PREVIOUS LEG report.
(3) Push the '>' adjacent to the related CFDS failure message:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU LAST LEG/PREVIOUS LEG report.
(3) Push the '>' adjacent to the related CFDS failure message:
- the MCDU menu shows:
ECB INTERNAL FAILURE
Subtask 49-00-81-810-069-A ** ON A/C NOT FOR ALL
A. If the APU GND SCANNING gives the maintenance message
ECB (59KD)
With the maintenance message associated with one of the Fault Code Numbers (FCN) that follow:
15, 25, 32, 147, 170, 171, 172, 185, 186
20, 50, 53, 181, 182, 184, 233, 236
75, 80 or 84
Subtask 49-00-81-710-083-A ** ON A/C NOT FOR ALL ECB (59KD)
With the maintenance message associated with one of the Fault Code Numbers (FCN) that follow:
15, 25, 32, 147, 170, 171, 172, 185, 186
20, 50, 53, 181, 182, 184, 233, 236
75, 80 or 84
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do a check of the APU GND SCANNING menu to verify the fault is not present.