W DOC AIRBUS | TSM A320F

#quot#START IN PROGRESS#quot#- Signal Fault (131-9(A))


TASK 49-00-81-810-865-A
"START IN PROGRESS"- Signal Fault (131-9(A))


1. Possible Causes
  • APU START IN PROGRESS SHOWS CIRCUIT FAILURE
  • BOARD-ANN LT TEST & INTFC [7LP]
  • aircraft wiring
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-14-00-710-001
Operational Test of the Lights
AMM 33-14-33-000-001
Removal of the Annunciator-Light Test and Interface-Board
AMM 33-14-33-400-001
Installation of the Annunciator-Light Test and Interface-Board
ASM 494201
AMM 49-61-34-000-003
Removal of the Electronic Control Box (ECB) (131-9(A))
AMM 49-61-34-400-003
Installation of the Electronic Control Box (ECB) (131-9(A))
3. Fault Confirmation
Subtask 49-00-81-710-080-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
   (1) Put the APU MASTER SW to the ON position.
   (2) Get access to the APU LAST LEG/PREVIOUS LEG report.
   (3) Push the '>'-key adjacent to the related CFDS failure message.
   (4) If the MCDU menu shows:
APU START IN PROGRESS SHOWS CIRCUIT FAILURE

  • do the Fault Confirmation that follows:
     (a) Get access to the APU GND SCANNING menu.
4. Fault Isolation
Subtask 49-00-81-810-068-A ** ON A/C NOT FOR ALL
A. If the APU GND SCANNING menu gives the maintenance message:

WRG: START IN PROGRESS

associated with Fault Code Number (FCN) 144

   (1) If AVAIL/ON annunciator lights on the APU START P/B (2KA) do not come ON:
     (a) If the fault continues:
  • replace the APU START P/B (2KA).
   (2) If AVAIL/ON annunciator lights on the APU START P/B (2KA) come ON:
  • do a check and repair of the aircraft wiring from the ECB (59KD) AB/H9 to the RELAY-ANNUNCIATOR-LIGHT TEST AND INTERFACE-BOARD (7LP) A/15 ASM 494201.
   (3) If the fault continues:
Subtask 49-00-81-710-081-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:37 UTC