APU AUTO SHUTDOWN - REVERSE FLOW, Reverse Flow Condition for min. 6 Seconds (131-9(A))
TASK 49-00-81-810-847-A
APU AUTO SHUTDOWN - REVERSE FLOW, Reverse Flow Condition for min. 6 Seconds (131-9(A))
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-184-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-128-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:35 UTC
APU AUTO SHUTDOWN - REVERSE FLOW, Reverse Flow Condition for min. 6 Seconds (131-9(A))
1. Possible Causes
- NO LRU FAULT DETECTED
- blockage of the APU inlet
- CHECK VALVE-APU BLEED [7260HM]
tube of the DIFFERENTIAL PRESSURE TRANSDUCER (P24) tube of the TOTAL PRESSURE TRANSDUCER (P23) DIFFERENTIAL PRESSURE TRANSDUCER (P24) TOTAL PRESSURE TRANSDUCER (P23) SURGE CONTROL VALVE (P18) - ELECTRONIC CONTROL BOX [59KD]
tube of the DIFFERENTIAL PRESSURE TRANSDUCER (8043KM). tube of the TOTAL PRESSURE TRANSDUCER (8044KM). DIFFERENTIAL PRESSURE TRANSDUCER (8043KM) TOTAL PRESSURE TRANSDUCER (8044KM) SURGE CONTROL VALVE (8058KM)
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | AIR SOURCE 2 BAR (30 PSI) - REGULATED, FILTERED, DRY |
| No specific | AR | PLUG - BLANKING |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-12-51-000-002 | Removal of the APU Bleed Check-Valve |
| AMM 36-12-51-200-001 | Remove and Check Auxiliary Power Unit Bleed Check-Valve for Condition |
| AMM 36-12-51-400-002 | Installation of the APU Bleed Check-Valve |
| AMM 49-00-00-860-008 | APU Start by External Power |
| AMM 49-51-16-000-002 | Removal of the Transducer - Differential Pressure (131-9(A)) |
| AMM 49-51-16-400-002 | Installation of the Transducer - Differential Pressure (131-9(A)) |
| AMM 49-51-17-000-002 | Removal of the Transducer - Total Pressure (131-9(A)) |
| AMM 49-51-17-400-002 | Installation of the Transducer - Total Pressure (131-9(A)) |
| AMM 49-51-52-000-003 | Removal of the Surge Control Valve (131-9(A)) |
| AMM 49-51-52-400-003 | Installation of the Surge Control Valve (131-9(A)) |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-184-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
NO LRU FAULT DETECTED
Subtask 49-00-81-810-128-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
REVERSE FLOW
DP XDCR P24/PT XDCR P23/ SURGE CONTROL VALVE P18
associated with Fault Code Numbers (FCN) 216
- install the tube of the DIFFERENTIAL PRESSURE TRANSDUCER (P24) AMM 49-51-16-400-002.
- install the tube of the TOTAL PRESSURE TRANSDUCER (P23) AMM 49-51-17-400-002.
(c) If the fault continues:
- replace theDIFFERENTIAL PRESSURE TRANSDUCER (P24) AMM 49-51-16-000-002 and AMM 49-51-16-400-002.
- replace theTOTAL PRESSURE TRANSDUCER (P23) AMM 49-51-17-000-002 and AMM 49-51-17-400-002.
(d) If the fault continues:
- replace theSURGE CONTROL VALVE (P18) AMM 49-51-52-000-003 and AMM 49-51-52-400-003.
(e) If the fault continues:
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
Subtask 49-00-81-810-128-B ** ON A/C NOT FOR ALL REVERSE FLOW
DP XDCR P24/PT XDCR P23/ SURGE CONTROL VALVE P18
associated with Fault Code Numbers (FCN) 216
- do a check for blockage of the APU inlet .
- do a check of the CHECK VALVE-APU BLEED [7260HM] AMM 36-12-51-200-001.
- replace the CHECK VALVE-APU BLEED [7260HM] AMM 36-12-51-000-002 and AMM 36-12-51-400-002.
- do a check for damage/contamination of the DIFFERENTIAL PRESSURE TRANSDUCER (P24) and TOTAL PRESSURE TRANSDCER (P23)
- remove thetube of the DIFFERENTIAL PRESSURE TRANSDUCER (P24) AMM 49-51-16-000-002.
- remove thetube of the TOTAL PRESSURE TRANSDUCER (P23) AMM 49-51-17-000-002.
- put PLUG - BLANKING in the openings.
- use a AIR SOURCE 2 BAR (30 PSI) - REGULATED, FILTERED, DRY to remove unwanted materials out of the tubes.
NOTE: It is recommended to use a pressure of 60-90 psig (4.14-6.20 bar) of filtered air or nitrogen to blow the air through the tubes.
- remove the plugs from the openings. - install the tube of the DIFFERENTIAL PRESSURE TRANSDUCER (P24) AMM 49-51-16-400-002.
- install the tube of the TOTAL PRESSURE TRANSDUCER (P23) AMM 49-51-17-400-002.
(c) If the fault continues:
- replace the
- replace the
(d) If the fault continues:
- replace the
(e) If the fault continues:
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
REVERSE FLOW
PRESS XDCRS (8044KM) /(8043KM) / SCV (8058KM)
associated with Fault Code Numbers (FCN) 216
- install the tube of the DIFFERENTIAL PRESSURE TRANSDUCER (8043KM) AMM 49-51-16-400-002.
- install the tube of the TOTAL PRESSURE TRANSDUCER (8044KM) AMM 49-51-17-400-002.
(c) If the fault continues:
- replace theDIFFERENTIAL PRESSURE TRANSDUCER (8043KM) AMM 49-51-16-000-002 and AMM 49-51-16-400-002.
- replace theTOTAL PRESSURE TRANSDUCER (8044KM) AMM 49-51-17-000-002 and AMM 49-51-17-400-002.
(d) If the fault continues:
- replace theSURGE CONTROL VALVE (8058KM) AMM 49-51-52-000-003 and AMM 49-51-52-400-003.
(e) If the fault continues:
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
Subtask 49-00-81-710-185-A ** ON A/C NOT FOR ALL REVERSE FLOW
PRESS XDCRS (8044KM) /(8043KM) / SCV (8058KM)
associated with Fault Code Numbers (FCN) 216
- do a check for blockage of the APU inlet .
- do a check of the CHECK VALVE-APU BLEED [7260HM] AMM 36-12-51-200-001.
- replace the CHECK VALVE-APU BLEED [7260HM] AMM 36-12-51-000-002 and AMM 36-12-51-400-002.
- do a check for damage/contamination of the DIFFERENTIAL PRESSURE TRANSDUCER (8043KM) and TOTAL PRESSURE TRANSDCER (8044KM).
- remove thetube of the DIFFERENTIAL PRESSURE TRANSDUCER (8043KM). AMM 49-51-16-000-002.
- remove thetube of the TOTAL PRESSURE TRANSDUCER (8044KM). AMM 49-51-17-000-002.
- put PLUG - BLANKING in the openings.
- use a AIR SOURCE 2 BAR (30 PSI) - REGULATED, FILTERED, DRY to remove unwanted materials out of the tubes.
NOTE: It is recommended to use a pressure of 60-90 psig (4.14-6.20 bar) of filtered air or nitrogen to blow the air through the tubes.
- remove the plugs from the openings. - install the tube of the DIFFERENTIAL PRESSURE TRANSDUCER (8043KM) AMM 49-51-16-400-002.
- install the tube of the TOTAL PRESSURE TRANSDUCER (8044KM) AMM 49-51-17-400-002.
(c) If the fault continues:
- replace the
- replace the
(d) If the fault continues:
- replace the
(e) If the fault continues:
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do the test given in Para. 3.