W DOC AIRBUS | TSM A320F

APU AUTO SHUTDOWN - NO ACCELERATION, De-Oil Solenoid Fault (131-9(A))


TASK 49-00-81-810-838-A
APU AUTO SHUTDOWN - NO ACCELERATION, De-Oil Solenoid Fault (131-9(A))


1. Possible Causes
  • DEOIL SOLENOID SHOWS OPEN CIRCUIT
  • DEOIL SOLENOID SHOWS CIRCUIT FAILURE
  • damage/contamination of the electrical connector P15
  • DE-OIL SOLENOID VALVE (P15)
  • aircraft wiring
  • ELECTRONIC CONTROL BOX [59KD]
  • DE-OIL SOLENOID VALVE (8083KM)
  • DATA MEMORY MODULE (P20)
  • DATA MEMORY MODULE (8062KM)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
MULTIMETER - STANDARD
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 49-00-00-860-008
APU Start by External Power
ASM 496104
AMM 49-61-34-000-003
Removal of the Electronic Control Box (ECB) (131-9(A))
AMM 49-61-34-400-003
Installation of the Electronic Control Box (ECB) (131-9(A))
AMM 49-73-32-000-001
Removal of the Data Memory Module (131-9(A))
AMM 49-73-32-400-001
Installation of the Data Memory Module (131-9(A))
AMM 49-91-49-000-003
Removal of De-Oil Solenoid (131-9(A))
AMM 49-91-49-400-003
Installation of De-Oil Solenoid (131-9(A))
3. Fault Confirmation
Subtask 49-00-81-710-164-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
   (1) Put the APU MASTER SW to the ON position.
   (2) Get access to the APU SHUTDOWN report.
   (3) Push the '>' adjacent to LRU DATA:
  • the MCDU menu shows
    DEOIL SOLENOID SHOWS OPEN CIRCUIT

    DEOIL SOLENOID SHOWS CIRCUIT FAILURE

   (4) Start the APU and apply Bleed Air for 20 seconds, minimum AMM 49-00-00-860-008.
4. Fault Isolation
Subtask 49-00-81-810-115-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:

NO ACCELERATION
DEOIL SOLENOID P15

associated with the Fault Code Number (FCN) 133

  • do a check for damage/contamination of the electrical connector P15 of the DE-OIL SOLENOID VALVE (P15)
   (1) If the electrical connector P15 is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connector P15 is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across the pin 1 to the pin 2 of the DE-OIL SOLENOID VALVE (P15)
     (a) If the resistance value is > 80 Ohms:
     (b) If the resistance value is in the specified limit:
  • do a check and repair of the aircraft wiring from
    the ECB (59KD) AB/4J to the DE-OIL SOLENOID (P15) P15/1
    and
    the DE-OIL SOLENOID (P15) P15/2 to GND
    ASM 496104.
       1 If the fault continues:
Subtask 49-00-81-810-123-A ** ON A/C NOT FOR ALL
B. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:

NO ACCELERATION
DEOIL SOLENOID P15

associated with the Fault Code Number (FCN) 134

  • do a check for damage/contamination of the electrical connector P15 of the DE-OIL SOLENOID VALVE (P15)
   (1) If the electrical connector P15 is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connector P15 is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across
    pin 1 and pin 2; required value > 10 Ohms
    and
    pin 1 and pin 3; required value > 100 kOhms
    of the DE-OIL SOLENOID VALVE (P15)
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • use a MULTIMETER - STANDARD to do a resistance check across
    pin 2 and pin 3; required value > 10 Ohms
    and
    pin 2 and pin 15; required value > 100 kOhms
    of the DATA MEMORY MODULE (P20)
       1 If the resistance values are out of the specified limits:
       2 If the resistance values are in the specified limits:
  • do a check and repair of the aircraft wiring from
    the ECB (59KD) AB/4J to the DE-OIL SOLENOID (P15) P15/1
    and
    the DE-OIL SOLENOID (P15) P15/2 to GND
    and
    the ECB (59KD) AB/4J to the DATA MEMORY MODULE (P20) P20/2
    and
    the DATA MEMORY MODULE (P20) P20/3 to GND
    ASM 496104.
         a If the fault continues:
Subtask 49-00-81-810-115-B ** ON A/C NOT FOR ALL
C. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:

NO ACCELERATION
DEOIL SOLENOID (8083KM)

associated with the Fault Code Number (FCN) 133

  • do a check for damage/contamination of the electrical connector P15 of the DE-OIL SOLENOID VALVE (8083KM)
   (1) If the electrical connector P15 is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connector P15 is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across the pin 1 to the pin 2 of the DE-OIL SOLENOID VALVE (8083KM)
     (a) If the resistance value is > 80 Ohms:
     (b) If the resistance value is in the specified limit:
  • do a check and repair of the aircraft wiring from
    the ECB (59KD) AB/4J to the DE-OIL SOLENOID (8083KM) P15/1
    and
    the DE-OIL SOLENOID (8083KM) P15/2 to GND
    ASM 496104.
       1 If the fault continues:
Subtask 49-00-81-810-123-B ** ON A/C NOT FOR ALL
D. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:

NO ACCELERATION
DEOIL SOLENOID (8083KM)

associated with the Fault Code Number (FCN) 134

  • do a check for damage/contamination of the electrical connector P15 of the DE-OIL SOLENOID VALVE (8083KM)
   (1) If the electrical connector P15 is damaged/contaminated:
  • do a repair/cleaning.
   (2) If the electrical connector P15 is OK:
  • use a MULTIMETER - STANDARD to do a resistance check across
    pin 1 and pin 2; required value > 10 Ohms
    and
    pin 1 and pin 3; required value > 100 kOhms
    of the DE-OIL SOLENOID VALVE (8083KM)
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • use a MULTIMETER - STANDARD to do a resistance check across
    pin 2 and pin 3; required value > 10 Ohms
    and
    pin 2 and pin 15; required value > 100 kOhms
    of the DATA MEMORY MODULE (8062KM)
       1 If the resistance values are out of the specified limits:
       2 If the resistance values are in the specified limits:
  • do a check and repair of the aircraft wiring from
    the ECB (59KD) AB/4J to the DE-OIL SOLENOID (8083KM) P15/1
    and
    the DE-OIL SOLENOID (8083KM) P15/2 to GND
    and
    the ECB (59KD) AB/4J to the DATA MEMORY MODULE (8062KM) P20/2
    and
    the DATA MEMORY MODULE (8062KM) P20/3 to GND
    ASM 496104.
         a If the fault continues:
Subtask 49-00-81-710-165-A ** ON A/C NOT FOR ALL
E. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:35 UTC