APU AUTO SHUTDOWN - NO ACCELERATION, Main Start-Contactor Fault (131-9(A))
TASK 49-00-81-810-831-A
APU AUTO SHUTDOWN - NO ACCELERATION, Main Start-Contactor Fault (131-9(A))
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-150-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-108-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:34 UTC
APU AUTO SHUTDOWN - NO ACCELERATION, Main Start-Contactor Fault (131-9(A))
1. Possible Causes
- MAIN START CONTACTOR SHOWS OPEN CIRCUIT
damage or contamination of electrical connection STRT MTR (+) - electrical connections
- aircraft wiring
damage and contamination of electrical connection STRT MTR (+)
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-00-00-860-008 | APU Start by External Power |
| ASM 494201 | |
| AMM 49-42-51-400-006 | Installation of the Starter Motor (131-9(A)) |
Subtask 49-00-81-710-150-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(3) Push the '>' adjacent to LRU DATA:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
NOTE: Make sure that the A/C batteries are switched ON!
(2) Get access to the APU SHUTDOWN report. (3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
MAIN START CONTACTOR SHOWS OPEN CIRCUIT
Subtask 49-00-81-810-108-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
NO ACCELERATION
ACFT BAT NOT SELECTED/CONTACTOR (5KA)
related to Fault Code Number (FCN) 123
(2) If electrical connection STRT MTR (+) is damaged or has contamination:
Subtask 49-00-81-810-108-B ** ON A/C NOT FOR ALL NO ACCELERATION
ACFT BAT NOT SELECTED/CONTACTOR (5KA)
related to Fault Code Number (FCN) 123
- Do a check for
damage or contamination of electrical connection STRT MTR (+) of the STARTER MOTOR (8KA).
(2) If electrical connection STRT MTR (+) is damaged or has contamination:
- Repair or clean as necessary.
- Use a MULTIMETER - STANDARD to do a resistance check of the aircraft wiring between electrical connection STRT MTR (+) and ECB (59KD) AB/10J.
- Replace the aircraft wiring.
- Do a check and repair the aircraft wiring from
MAIN-START CONTACTOR (5KA) B/5 to APU MASTER SW P/BSW (14KD) A/D1
and
MAIN-START CONTACTOR (5KA) B/3 to ECB (59KD) AC/1
and
MAIN-START CONTACTOR (5KA) A/D to BACK-UP-START CONTACTOR (10KA) A/F
and
ECB (59KD) AB/10J to electrical connection STRT MTR (+) of the STARTER MOTOR (8KA)
ASM 494201.
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
NO ACCELERATION
ACFT BAT NOT SELECTED/CONTACTOR (5KA)
related to Fault Code Number (FCN) 123
(2) If electrical connection STRT MTR (+) is damaged or has contamination:
Subtask 49-00-81-710-151-A ** ON A/C NOT FOR ALL NO ACCELERATION
ACFT BAT NOT SELECTED/CONTACTOR (5KA)
related to Fault Code Number (FCN) 123
- Do a check for
damage and contamination of electrical connection STRT MTR (+) of the STARTER MOTOR (8KA).
(2) If electrical connection STRT MTR (+) is damaged or has contamination:
- Repair or clean as necessary.
- Use a MULTIMETER - STANDARD to do a resistance check of the aircraft wiring between electrical connection STRT MTR (+) and ECB (59KD) AB/10J.
- Replace the aircraft wiring.
- Do a check and repair the aircraft wiring from
MAIN-START CONTACTOR (5KA) B/5 to APU MASTER SW P/BSW (14KD) A/D1
and
MAIN-START CONTACTOR (5KA) B/3 to ECB (59KD) AC/1
and
ECB (59KD) AB/10J to electrical connection STRT MTR (+) of the STARTER MOTOR (8KA)
ASM 494201.
B. Do the test given in Para. 3.