APU AUTO SHUTDOWN - HIGH OIL TEMPERATURE, High Oil Temperature (131-9(A))


TASK 49-00-81-810-829-A
APU AUTO SHUTDOWN - HIGH OIL TEMPERATURE, High Oil Temperature (131-9(A))


1. Possible Causes
  • NO LRU FAULT DETECTED
  • blockage of the air intake duct
  • blockage of the APU inlet housing
  • OIL COOLER ducting
  • OIL TEMPERATURE SENSOR
  • OIL COOLER
  • COOLING-FAN ASSEMBLY
  • GEN-APU [8XS]
  • OIL TEMPERATURE SENSOR (8092KM)
  • OIL COOLER (8079KM)
  • COOLING-FAN ASSEMBLY (8053KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-23-51-000-001
Removal of the APU Generator
AMM 24-23-51-400-001
Installation of the APU Generator
AMM 49-00-00-860-008
APU Start by External Power
AMM 49-52-51-000-002
Removal of the Cooling Fan (131-9(A))
AMM 49-52-51-400-002
Installation of the Cooling Fan (131-9(A))
AMM 49-91-44-000-004
Removal of the Oil Cooler (131-9(A))
AMM 49-91-44-400-004
Installation of the Oil Cooler (131-9(A))
AMM 49-94-15-000-001
Removal of Oil Temperature Sensor (131-9(A))
AMM 49-94-15-400-001
Installation of Oil Temperature Sensor (131-9(A))
3. Fault Confirmation
Subtask 49-00-81-710-144-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
   (1) Put the APU MASTER SW to the ON position.
   (2) Get access to the APU SHUTDOWN report.
   (3) Push the '>' adjacent to LRU DATA:
  • the MCDU menu shows
    NO LRU FAULT DETECTED

   (4) Start the APU and apply Bleed Air for 20 seconds, minimum AMM 49-00-00-860-008.
4. Fault Isolation
Subtask 49-00-81-810-105-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:

HIGH OIL TEMPERATURE
OIL COOLER/COOLING FAN ASSEMBLY

associated with the Fault Code Number (FCN) 211

  • do a check for
    blockage of the air intake duct
    blockage of the APU inlet housing
    OIL COOLER ducting for blockage or contamination.
   (1) If there is no blockage or contamination:
     (a) If the fault continues:
     (b) If the fault continues:
     (c) If the fault continues:
Subtask 49-00-81-810-105-B ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:

HIGH OIL TEMPERATURE
OIL COOLER (8079KM) / COOLING FAN (8053KM)

associated with the Fault Code Number (FCN) 211

  • do a check for
    blockage of the air intake duct
    blockage of the APU inlet housing
    OIL COOLER ducting for blockage or contamination.
   (1) If there is no blockage or contamination:
     (a) If the fault continues:
     (b) If the fault continues:
     (c) If the fault continues:
Subtask 49-00-81-710-145-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.