APU AUTO SHUTDOWN - AIR INTAKE NOT OPEN, Air Intake Fault (131-9(A))
TASK 49-00-81-810-828-A
APU AUTO SHUTDOWN - AIR INTAKE NOT OPEN, Air Intake Fault (131-9(A))
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-146-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-106-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:34 UTC
APU AUTO SHUTDOWN - AIR INTAKE NOT OPEN, Air Intake Fault (131-9(A))
1. Possible Causes
- INLET FLAP SHOWS FLAP LOSS OF OPEN INDICATION
- INLET FLAP SHOWS FLAP FAILED TO OPEN
- INLET FLAP SHOWS FLAP CLOSE CIRCUIT OPEN
- INLET FLAP SHOWS FLAP OPEN HIGH CURRENT
damage/contamination of the electrical connector 7527VC - aircraft wiring
AIR INTAKE FLAP ACTUATOR (4015KM) - ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-00-00-860-008 | APU Start by External Power |
| ASM 491601 | |
| AMM 49-16-51-000-003 | Removal of the Air-Intake Flap Actuator (131-9(A)) |
| AMM 49-16-51-400-003 | Installation of the Air-Intake Flap Actuator (131-9(A)) |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-146-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
INLET FLAP SHOWS FLAP LOSS OF OPEN INDICATION
or
INLET FLAP SHOWS FLAP FAILED TO OPEN
or
INLET FLAP SHOWS FLAP CLOSE CIRCUIT OPEN
or
INLET FLAP SHOWS FLAP OPEN HIGH CURRENT
Subtask 49-00-81-810-106-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
AIR INTAKE NOT OPEN
AIR INTAKE FLAP ACTUATOR
associated with Fault Code Numbers (FCN) 64, 65, 68, 70 or 71
Subtask 49-00-81-810-106-B ** ON A/C NOT FOR ALL AIR INTAKE NOT OPEN
AIR INTAKE FLAP ACTUATOR
associated with Fault Code Numbers (FCN) 64, 65, 68, 70 or 71
- do a check for
damage/contamination of the electrical connector 7527VC of the AIR INTAKE FLAP-ACTUATOR.
- do a repair/cleaning.
- do a check and repair of the aircraft wiring from
the ECB (59KD) AC/5,4 to the electrical connector 7527VCA/J,K
and
the ECB (59KD) AB/G2,G3,G4,G5 to the electrical connector 7527VCA/D,C,E,B
and
the electrical connector 7527VCA/A,L,F, to GND
ASM 491601.
- replace the
AIR INTAKE FLAP ACTUATOR (4015KM) AMM 49-16-51-000-003 and AMM 49-16-51-400-003.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
AIR INTAKE NOT OPEN
AIR INTAKE FLAP ACTUATOR (4015KM)
associated with Fault Code Numbers (FCN) 64, 65, 68, 70 or 71
Subtask 49-00-81-710-147-A ** ON A/C NOT FOR ALL AIR INTAKE NOT OPEN
AIR INTAKE FLAP ACTUATOR (4015KM)
associated with Fault Code Numbers (FCN) 64, 65, 68, 70 or 71
- do a check for
damage/contamination of the electrical connector 7527VC of the AIR INTAKE FLAP-ACTUATOR (4015KM).
- do a repair/cleaning.
- do a check and repair of the aircraft wiring from
the ECB (59KD) AC/5,4 to the electrical connector 7527VCA/J,K
and
the ECB (59KD) AB/G2,G3,G4,G5 to the electrical connector 7527VCA/D,C,E,B
and
the electrical connector 7527VCA/A,L,F, to GND
ASM 491601.
- replace the
AIR INTAKE FLAP ACTUATOR (4015KM) AMM 49-16-51-000-003 and AMM 49-16-51-400-003.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do the test given in Para. 3.