APU AUTO SHUTDOWN - SENSOR FAILURE, EGT2 Sensor Fault and ECB internal Fault (131-9(A))
TASK 49-00-81-810-815-A
APU AUTO SHUTDOWN - SENSOR FAILURE, EGT2 Sensor Fault and ECB internal Fault (131-9(A))
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-116-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-089-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:33 UTC
APU AUTO SHUTDOWN - SENSOR FAILURE, EGT2 Sensor Fault and ECB internal Fault (131-9(A))
1. Possible Causes
- EGT 2 SENSOR FAILURE AND ECB INTERNAL FAILURE
- EGT THERMOCOUPLE RAKE 2
- ELECTRONIC CONTROL BOX [59KD]
EGT THERMOCOUPLE RAKE (8057KM2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-00-00-860-008 | APU Start by External Power |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-72-15-000-002 | Removal of the Thermocouples (131-9(A)) |
| AMM 49-72-15-400-003 | Installation of the Thermocouples (131-9(A)) |
Subtask 49-00-81-710-116-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
EGT 2 SENSOR FAILURE AND ECB INTERNAL FAILURE
Subtask 49-00-81-810-089-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
SENSOR FAIL
EGT TCPLE RAKE 2 + ECB (59KD)
associated with the Fault Code Number (FCN) 37
Subtask 49-00-81-810-089-B ** ON A/C NOT FOR ALL SENSOR FAIL
EGT TCPLE RAKE 2 + ECB (59KD)
associated with the Fault Code Number (FCN) 37
- replace the EGT THERMOCOUPLE RAKE 2 AMM 49-72-15-000-002 and AMM 49-72-15-400-003 and the
ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
SENSOR FAIL
EGT TCPLE RAKE (8057KM1) AND ECB (59KD)
associated with the Fault Code Number (FCN) 37
Subtask 49-00-81-710-117-A ** ON A/C NOT FOR ALL SENSOR FAIL
EGT TCPLE RAKE (8057KM1) AND ECB (59KD)
associated with the Fault Code Number (FCN) 37
- replace the
EGT THERMOCOUPLE RAKE (8057KM2) AMM 49-72-15-000-002 and AMM 49-72-15-400-003 and the
ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do the test given in Para. 3.