APU AUTO SHUTDOWN - ECB FAILURE, ECB Internal Fault (131-9(A))
TASK 49-00-81-810-804-A
APU AUTO SHUTDOWN - ECB FAILURE, ECB Internal Fault (131-9(A))
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-096-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-079-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:32 UTC
APU AUTO SHUTDOWN - ECB FAILURE, ECB Internal Fault (131-9(A))
1. Possible Causes
- ECB INTERNAL FAILURE
- ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 49-00-00-860-008 | APU Start by External Power |
| AMM 49-61-34-000-003 | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| AMM 49-61-34-400-003 | Installation of the Electronic Control Box (ECB) (131-9(A)) |
Subtask 49-00-81-710-096-A ** ON A/C NOT FOR ALL
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
4. Fault Isolation(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
ECB INTERNAL FAILURE
Subtask 49-00-81-810-079-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
ECB FAILURE
ECB (59KD)
with the associated Fault Code Numbers (FCN) 5, 176, 177, 178, 179, 180 or 230
Subtask 49-00-81-710-097-A ** ON A/C NOT FOR ALL ECB FAILURE
ECB (59KD)
with the associated Fault Code Numbers (FCN) 5, 176, 177, 178, 179, 180 or 230
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-003 and AMM 49-61-34-400-003.
B. Do the test given in Para. 3.