Backup Start Contactor output open (APS 3200)
TASK 49-00-00-810-987-A
Backup Start Contactor output open (APS 3200)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-00-710-392-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 49-00-00-810-350-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:29 UTC
Backup Start Contactor output open (APS 3200)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2052210 | |
| ESPM 2053210 | |
| AMM 49-00-00-710-008 | Operational Test of the APU |
| ASM 494201 | |
| AMM 49-42-51-000-007 | Removal of the Starter Motor (APS 3200) |
| AMM 49-42-51-400-007 | Installation of the Starter Motor (APS 3200) |
| AMM 49-42-55-000-001 | Removal of the Start Contactors |
| AMM 49-42-55-400-001 | Installation of the Start Contactors |
Subtask 49-00-00-710-392-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 49-00-00-810-350-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:
CONTACTOR (10KA)
Fault Code Number: 018 or 086
Subtask 49-00-00-710-393-A ** ON A/C NOT FOR ALL CONTACTOR (10KA)
Fault Code Number: 018 or 086
- replace the CONTACTOR-BACK-UP START [10KA] AMM 49-42-55-000-001 and AMM 49-42-55-400-001.
- do a check and repair the wiring between the Back-Up Start Contactor(10KA) and the ECB (59KD) ASM 494201 ESPM 2052210 ESPM 2053210.
- do a check and repair of the wiring between ECB (59KD) AB/J10 and STARTER MOTOR (8KA) positive terminal ASM 494201 ESPM 2052210 ESPM 2053210.
- replace the MOTOR-STARTER [8KA] AMM 49-42-51-000-007 and AMM 49-42-51-400-007.
B. Do the test given in Para. 3.