W DOC AIRBUS | TSM A320F

PMG Fault (PMG and Cooling Fan Assy) (APS 3200)


TASK 49-00-00-810-982-A
PMG Fault (PMG and Cooling Fan Assy) (APS 3200)


1. Possible Causes
  • PMG and COOLING FAN ASSEMBLY (8055KM)
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-52-53-000-001
Removal of the PMG and Cooling Fan Assembly (APS 3200)
AMM 49-52-53-400-001
Installation of the PMG and Cooling Fan Assembly (APS 3200)
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-380-B ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-344-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:

COOLING FAN/PMG ASSY (8055KM):

   (1) If the fault continues:
     (a) If the fault continues:
Subtask 49-00-00-710-381-B ** ON A/C NOT FOR ALL
B. Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:34:29 UTC